Background: High plasma levels of activated Factor VII-Antithrombin complex (FVIIa-AT) have been associated with an increased risk of cardiovascular mortality in patients with stable coronary artery disease (CAD). Objectives: To investigate if FVIIa-AT levels are associated with activated factor X generation (FXaG) in modified assays. Patients/methods: Forty CAD patients were characterized for FVIIa-AT levels by ELISA and for FXaG in plasma. Novel fluorogenic FXaG assays, based on aptamers inhibiting thrombin and/or tissue factor pathway inhibitor (TFPI), were set up. Results: FXaG correlated with FVIIa-AT levels (RAUC = 0.393, P = 0.012). The combination of thrombin inhibition and FXaG potentiation by using anti-thrombin and anti-TFPI aptamers, respectively, favors the study of time parameters. The progressive decrease in lag time from the lowest to the highest FVIIa-AT quartile was magnified by combining TFPI and thrombin inhibitory aptamers, thus supporting increased FXaG activity in the coagulation initiation phase. By exploring FXaG rates across FVIIa-AT quartiles, the largest relative differences were detectable at the early times (the highest versus the lowest quartile; 5.0-fold, P = 0.005 at 45 s; 3.5-fold, P = 0.001 at 55 s), and progressively decreased over time (2.3-fold, P = 0.002 at 75 s; 1.8-fold, P = 0.008 at 95 s; 1.6-fold, P = 0.022 at 115 s). Association between high FVIIa-AT levels and increased FXaG was independent of F7 −323 A1/A2 polymorphism influencing FVIIa-AT levels. Conclusions: High FVIIa-AT plasma levels were associated with increased FXaG. Hypercoagulability features were specifically detectable in the coagulation initiation phase, which may have implications for cardiovascular risk prediction by either FVIIa-AT complex measurement or modified FXaG assays.

Aptamer-modified FXa generation assays to investigate hypercoagulability in plasma from patients with ischemic heart disease

Marcello Baroni
Primo
;
Barbara Lunghi;Giovanna Marchetti;Mirko Pinotti;Francesco Bernardi
Ultimo
2020

Abstract

Background: High plasma levels of activated Factor VII-Antithrombin complex (FVIIa-AT) have been associated with an increased risk of cardiovascular mortality in patients with stable coronary artery disease (CAD). Objectives: To investigate if FVIIa-AT levels are associated with activated factor X generation (FXaG) in modified assays. Patients/methods: Forty CAD patients were characterized for FVIIa-AT levels by ELISA and for FXaG in plasma. Novel fluorogenic FXaG assays, based on aptamers inhibiting thrombin and/or tissue factor pathway inhibitor (TFPI), were set up. Results: FXaG correlated with FVIIa-AT levels (RAUC = 0.393, P = 0.012). The combination of thrombin inhibition and FXaG potentiation by using anti-thrombin and anti-TFPI aptamers, respectively, favors the study of time parameters. The progressive decrease in lag time from the lowest to the highest FVIIa-AT quartile was magnified by combining TFPI and thrombin inhibitory aptamers, thus supporting increased FXaG activity in the coagulation initiation phase. By exploring FXaG rates across FVIIa-AT quartiles, the largest relative differences were detectable at the early times (the highest versus the lowest quartile; 5.0-fold, P = 0.005 at 45 s; 3.5-fold, P = 0.001 at 55 s), and progressively decreased over time (2.3-fold, P = 0.002 at 75 s; 1.8-fold, P = 0.008 at 95 s; 1.6-fold, P = 0.022 at 115 s). Association between high FVIIa-AT levels and increased FXaG was independent of F7 −323 A1/A2 polymorphism influencing FVIIa-AT levels. Conclusions: High FVIIa-AT plasma levels were associated with increased FXaG. Hypercoagulability features were specifically detectable in the coagulation initiation phase, which may have implications for cardiovascular risk prediction by either FVIIa-AT complex measurement or modified FXaG assays.
2020
Baroni, Marcello; Martinelli, Nicola; Lunghi, Barbara; Marchetti, Giovanna; Castagna, Annalisa; Stefanoni, Filippo; Pinotti, Mirko; Woodhams, Barry; O...espandi
File in questo prodotto:
File Dimensione Formato  
Baroni et al 2020 1-s2.0-S0049384820300803-main.pdf

solo gestori archivio

Descrizione: Full text editoriale
Tipologia: Full text (versione editoriale)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 1.03 MB
Formato Adobe PDF
1.03 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2436878
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact