Purpose: Esophageal pressure (Pes) is a minimally invasive advanced respiratory monitoring method with the potential to guide management of ventilation support and enhance specific diagnoses in acute respiratory failure patients. To date, the use of Pes in the clinical setting is limited, and it is often seen as a research tool only. Methods: This is a review of the relevant technical, physiological and clinical details that support the clinical utility of Pes. Results: After appropriately positioning of the esophageal balloon, Pes monitoring allows titration of controlled and assisted mechanical ventilation to achieve personalized protective settings and the desired level of patient effort from the acute phase through to weaning. Moreover, Pes monitoring permits accurate measurement of transmural vascular pressure and intrinsic positive end-expiratory pressure and facilitates detection of patient–ventilator asynchrony, thereby supporting specific diagnoses and interventions. Finally, some Pes-derived measures may also be obtained by monitoring electrical activity of the diaphragm. Conclusions: Pes monitoring provides unique bedside measures for a better understanding of the pathophysiology of acute respiratory failure patients. Including Pes monitoring in the intensivist’s clinical armamentarium may enhance treatment to improve clinical outcomes.

Esophageal and transpulmonary pressure in the clinical setting: meaning, usefulness and perspectives

Volta CA
Membro del Collaboration Group
;
Spadaro S
Membro del Collaboration Group
2016

Abstract

Purpose: Esophageal pressure (Pes) is a minimally invasive advanced respiratory monitoring method with the potential to guide management of ventilation support and enhance specific diagnoses in acute respiratory failure patients. To date, the use of Pes in the clinical setting is limited, and it is often seen as a research tool only. Methods: This is a review of the relevant technical, physiological and clinical details that support the clinical utility of Pes. Results: After appropriately positioning of the esophageal balloon, Pes monitoring allows titration of controlled and assisted mechanical ventilation to achieve personalized protective settings and the desired level of patient effort from the acute phase through to weaning. Moreover, Pes monitoring permits accurate measurement of transmural vascular pressure and intrinsic positive end-expiratory pressure and facilitates detection of patient–ventilator asynchrony, thereby supporting specific diagnoses and interventions. Finally, some Pes-derived measures may also be obtained by monitoring electrical activity of the diaphragm. Conclusions: Pes monitoring provides unique bedside measures for a better understanding of the pathophysiology of acute respiratory failure patients. Including Pes monitoring in the intensivist’s clinical armamentarium may enhance treatment to improve clinical outcomes.
2016
Mauri, T; Yoshida, T; Bellani, G; Goligher, Ec; Carteaux, G; Rittayamai, N; Mojoli, F; Chiumello, D; Piquilloud, L; Grasso, S; Jubran, A; Laghi, F; Magder, S; Pesenti, A; Loring, S; Gattinoni, L; Talmor, D; Blanch, L; Amato, M; Chen, L; Brochard, L; Mancebo, J; the PLeUral pressure working, Group; Volta, Ca; Spadaro, S
File in questo prodotto:
File Dimensione Formato  
Mauri2016_Article_EsophagealAndTranspulmonaryPre.pdf

solo gestori archivio

Tipologia: Full text (versione editoriale)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 2.12 MB
Formato Adobe PDF
2.12 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
134_2016_4400_MOESM1_ESM (1).pdf

accesso aperto

Descrizione: Supplementary materials
Tipologia: Altro materiale allegato
Licenza: PUBBLICO - Pubblico con Copyright
Dimensione 747.47 kB
Formato Adobe PDF
747.47 kB Adobe PDF Visualizza/Apri

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2414659
Citazioni
  • ???jsp.display-item.citation.pmc??? 146
  • Scopus 323
  • ???jsp.display-item.citation.isi??? 289
social impact