Background: The orthodontics industry has paid great attention to the aesthetics of orthodontic appliances, seeking to make them as invisible as possible. There are several advantages to clear aligner systems, including aesthetics, comfort, chairside time reduction, and the fact that they can be removed for meals and oral hygiene procedures. Methods: Five patients were each given a series of F22 aligners, each to be worn for 14 days and nights, with the exception of meal and brushing times. Patients were instructed to clean each aligner using a prescribed strategy, and sections of the used aligners were observed under SEM. One grey-scale SEM image was saved per aligner in JPEG format with an 8-bit colour depth, and a total of 45 measurements on the grey scale (“Value” variable) were made. This dataset was analysed statistically via repeated measures ANOVA to determine the effect of each of the nine cleaning strategies in each of the five patients. Results: A statistically significant difference in the efficacy of the cleaning strategies was detected. Specifically, rinsing with water alone was significantly less efficacious, and a combination of cationic detergent solution and ultrasonication was significantly more efficacious than the other methods (p < 0.05). Conclusions: Of the nine cleaning strategies examined, only that involving 5 min of ultrasonication at 42 k Hz combined with a 0.3% germicidal cationic detergent was observed to be statistically effective at removing the bacterial biofilm from the surface of F22 aligners.

Comparative SEM analysis of nine F22 aligner cleaning strategies

Lombardo, Luca;CERVINARA, FRANCESCA;Oliverio, Teresa;Siciliani, Giuseppe
2017

Abstract

Background: The orthodontics industry has paid great attention to the aesthetics of orthodontic appliances, seeking to make them as invisible as possible. There are several advantages to clear aligner systems, including aesthetics, comfort, chairside time reduction, and the fact that they can be removed for meals and oral hygiene procedures. Methods: Five patients were each given a series of F22 aligners, each to be worn for 14 days and nights, with the exception of meal and brushing times. Patients were instructed to clean each aligner using a prescribed strategy, and sections of the used aligners were observed under SEM. One grey-scale SEM image was saved per aligner in JPEG format with an 8-bit colour depth, and a total of 45 measurements on the grey scale (“Value” variable) were made. This dataset was analysed statistically via repeated measures ANOVA to determine the effect of each of the nine cleaning strategies in each of the five patients. Results: A statistically significant difference in the efficacy of the cleaning strategies was detected. Specifically, rinsing with water alone was significantly less efficacious, and a combination of cationic detergent solution and ultrasonication was significantly more efficacious than the other methods (p < 0.05). Conclusions: Of the nine cleaning strategies examined, only that involving 5 min of ultrasonication at 42 k Hz combined with a 0.3% germicidal cationic detergent was observed to be statistically effective at removing the bacterial biofilm from the surface of F22 aligners.
2017
Lombardo, Luca; Martini, Marco; Cervinara, Francesca; Spedicato, Giorgio Alfredo; Oliverio, Teresa; Siciliani, Giuseppe
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2392376
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 18
social impact