Trabecular Titanium is an advanced cellular solid structure, composed of regular multiplanar hexagonal interconnected cells that mimic the morphology of the trabecular bone. This biomaterial demonstrated improved mechanical properties and enhanced osteoinduction and osteoconduction in several in vitro and in vivo studies. The aim of this study was to assess Trabecular Titanium osseointegration by measuring periacetabular changes in bone mineral density (BMD) with dual-emission X-ray absorptiometry (DEXA). METHODS: 89 patients (91 hips) underwent primary total hip arthroplasty (THA) with acetabular Trabecular Titanium cups. Clinical (Harris Hip Score (HHS), SF-36) and radiographic assessment were performed preoperatively, and postoperatively at 7 days and at 3, 6, 12 and 24 months. DEXA analysis was performed only postoperatively, using the BMD values measured at 7 days as baselines. RESULTS: After an initial decrease from baseline to 6 months, BMD increased and progressively stabilised in all 3 regions of interest (ROIs). Median (IQR) HHS and SF-36 increased from 48 (39-62) and 49 (37-62) preoperatively to 99 (96-100) and 86 (79-92) at 24 months, indicating a considerable improvement in terms of pain relief, functional recovery and quality of life. BMD patterns and radiographic evaluation showed evident signs of periacetabular bone remodelling and osseointegration; all cups were stable at the final follow-up without radiolucent lines, loosening or osteolysis. No revisions were performed. CONCLUSIONS: After an initial reduction in periacetabular BMD, all 3 ROIs exhibited stabilisation or slight recovery. Although clinical outcomes and functional recovery proved satisfactory, longer follow-ups are necessary to assess this cup long-term survivorship.

Periacetabular bone densitometry after total hip arthroplasty with highly porous titanium cups: a 2-year follow-up prospective study

MASSARI, Leo
Primo
;
GIGLIOFIORITO, Gaetano;PARI, Carlotta;
2017

Abstract

Trabecular Titanium is an advanced cellular solid structure, composed of regular multiplanar hexagonal interconnected cells that mimic the morphology of the trabecular bone. This biomaterial demonstrated improved mechanical properties and enhanced osteoinduction and osteoconduction in several in vitro and in vivo studies. The aim of this study was to assess Trabecular Titanium osseointegration by measuring periacetabular changes in bone mineral density (BMD) with dual-emission X-ray absorptiometry (DEXA). METHODS: 89 patients (91 hips) underwent primary total hip arthroplasty (THA) with acetabular Trabecular Titanium cups. Clinical (Harris Hip Score (HHS), SF-36) and radiographic assessment were performed preoperatively, and postoperatively at 7 days and at 3, 6, 12 and 24 months. DEXA analysis was performed only postoperatively, using the BMD values measured at 7 days as baselines. RESULTS: After an initial decrease from baseline to 6 months, BMD increased and progressively stabilised in all 3 regions of interest (ROIs). Median (IQR) HHS and SF-36 increased from 48 (39-62) and 49 (37-62) preoperatively to 99 (96-100) and 86 (79-92) at 24 months, indicating a considerable improvement in terms of pain relief, functional recovery and quality of life. BMD patterns and radiographic evaluation showed evident signs of periacetabular bone remodelling and osseointegration; all cups were stable at the final follow-up without radiolucent lines, loosening or osteolysis. No revisions were performed. CONCLUSIONS: After an initial reduction in periacetabular BMD, all 3 ROIs exhibited stabilisation or slight recovery. Although clinical outcomes and functional recovery proved satisfactory, longer follow-ups are necessary to assess this cup long-term survivorship.
2017
Massari, Leo; Bistolfi, Alessandro; Grillo, Pier Paolo; Borré, Alda; Gigliofiorito, Gaetano; Pari, Carlotta; Francescotto, Andrea; Tosco, Piermario; D...espandi
File in questo prodotto:
File Dimensione Formato  
massari2017.pdf

solo gestori archivio

Descrizione: editoriale
Tipologia: Full text (versione editoriale)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 265.74 kB
Formato Adobe PDF
265.74 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
HIPINT-D-16-00089_V1_AU.pdf

accesso aperto

Descrizione: pre print
Tipologia: Pre-print
Licenza: Creative commons
Dimensione 535.69 kB
Formato Adobe PDF
535.69 kB Adobe PDF Visualizza/Apri

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2373824
Citazioni
  • ???jsp.display-item.citation.pmc??? 9
  • Scopus 24
  • ???jsp.display-item.citation.isi??? 25
social impact