Production of Cs and Fr isotopes from uranium carbide targets of a high density has been investigated at IRIS (Investigation Radioactive Isotopes at Synchrocyclotron), Gatchina. The UC target material with a density of 12 g/cm3 was prepared in a form of pellets. Two targets were tested on-line under the same temperature conditions: (a) a reference small target with a thickness of 4.5 g/cm2; (b) a heavier (so called intermediate) target with a thickness of 91 g/cm2. Yields and release efficiencies of nuclides with half-lives from some minutes to some milliseconds produced by 1 GeV protons in these targets are presented. It is remarkable that yields, even those of very short-lived isotopes such as 214Fr (T1/2 = 5 ms) and 219Fr (T1/2 = 20 ms), increase proportionally to the target thickness. A one month off-line heating test of the 91 g/cm2 target at a temperature of 2000 °C has been carried out successfully. The yields and release efficiencies of Cs and Fr measured on-line before and after the heating test coincided within the limits of measurement errors, thereby demonstrating the conservation of the target unit parameters. Based on these very promising results, a heavier target with a mass about 0.7 kg is prepared presently at IRIS.

Studies of uranium carbide targets of a high density

TONEZZER, Michele;
2008

Abstract

Production of Cs and Fr isotopes from uranium carbide targets of a high density has been investigated at IRIS (Investigation Radioactive Isotopes at Synchrocyclotron), Gatchina. The UC target material with a density of 12 g/cm3 was prepared in a form of pellets. Two targets were tested on-line under the same temperature conditions: (a) a reference small target with a thickness of 4.5 g/cm2; (b) a heavier (so called intermediate) target with a thickness of 91 g/cm2. Yields and release efficiencies of nuclides with half-lives from some minutes to some milliseconds produced by 1 GeV protons in these targets are presented. It is remarkable that yields, even those of very short-lived isotopes such as 214Fr (T1/2 = 5 ms) and 219Fr (T1/2 = 20 ms), increase proportionally to the target thickness. A one month off-line heating test of the 91 g/cm2 target at a temperature of 2000 °C has been carried out successfully. The yields and release efficiencies of Cs and Fr measured on-line before and after the heating test coincided within the limits of measurement errors, thereby demonstrating the conservation of the target unit parameters. Based on these very promising results, a heavier target with a mass about 0.7 kg is prepared presently at IRIS.
2008
Panteleev, V. N; Alyakrinskiy, O.; Barbui, M.; Barzakh, A. E.; Dubois, M.; Eleon, C.; Essabaa, S.; Fedorov, D. V.; Gaubert, G.; Ionan, A. M.; Ivanov, ...espandi
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2341392
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 13
social impact