OBJECTIVE: To assess the functional results of the Vibrant Soundbridge (VBS) placed on the round window (RW) in patients with mixed hearing loss. STUDY DESIGN: Retrospective evaluation of functional hearing, with measurements performed 7 to 9 months postoperatively. SETTINGS: Two tertiary referral hospital centers. SUBJECTS: Twelve individuals with mixed severe hearing loss associated with chronic suppurative otitis media and otosclerosis. INTERVENTION: Surgical placement of the VBS mechanical effector in close contact with the RW membrane to directly drive the inner ear fluids. MAIN OUTCOME MEASUREMENT: Functional hearing gain as analyzed via pure-tone audiometry and speech audiometry with VBS off and on in quiet and in noise. RESULTS: We observed a mean gain of 37.5 dB (0.5-4 kHz) with wide individual differences. The overall gain is mainly due to the air-bone gap recovery, whereas a further 12-dB mean improvement of air-conducted threshold is evident at 2 kHz. The speech reception threshold in quiet shows a mean gain of 24 dB, whereas in noise, it requires a signal-to-noise ratio 7 to 13 dB greater than normal-hearing controls. All patients are daily users of their VBS device. CONCLUSION: A middle ear implant capable of directly driving the cochlear fluids seems to be a promising alternative for individuals with a severe to profound mixed hearing loss. However, variability in hearing recovery is great, likely reflecting variability in responsiveness of the cochlea associated with chronic pathologic findings and, possibly, variability in how the VBS effector interfaces with the RW. Modifying the shape of the VBS effector can improve the mechanical coupling to the RW to better exploit the device's amplification power.

Coupling the vibrant soundbridge to cochlea round window: Auditory results in patients with mixed hearing loss

MARTINI, Alessandro;PROSSER, Silvano;GIARBINI, Nadia;
2009

Abstract

OBJECTIVE: To assess the functional results of the Vibrant Soundbridge (VBS) placed on the round window (RW) in patients with mixed hearing loss. STUDY DESIGN: Retrospective evaluation of functional hearing, with measurements performed 7 to 9 months postoperatively. SETTINGS: Two tertiary referral hospital centers. SUBJECTS: Twelve individuals with mixed severe hearing loss associated with chronic suppurative otitis media and otosclerosis. INTERVENTION: Surgical placement of the VBS mechanical effector in close contact with the RW membrane to directly drive the inner ear fluids. MAIN OUTCOME MEASUREMENT: Functional hearing gain as analyzed via pure-tone audiometry and speech audiometry with VBS off and on in quiet and in noise. RESULTS: We observed a mean gain of 37.5 dB (0.5-4 kHz) with wide individual differences. The overall gain is mainly due to the air-bone gap recovery, whereas a further 12-dB mean improvement of air-conducted threshold is evident at 2 kHz. The speech reception threshold in quiet shows a mean gain of 24 dB, whereas in noise, it requires a signal-to-noise ratio 7 to 13 dB greater than normal-hearing controls. All patients are daily users of their VBS device. CONCLUSION: A middle ear implant capable of directly driving the cochlear fluids seems to be a promising alternative for individuals with a severe to profound mixed hearing loss. However, variability in hearing recovery is great, likely reflecting variability in responsiveness of the cochlea associated with chronic pathologic findings and, possibly, variability in how the VBS effector interfaces with the RW. Modifying the shape of the VBS effector can improve the mechanical coupling to the RW to better exploit the device's amplification power.
2009
Beltrame, Am; Martini, Alessandro; Prosser, Silvano; Giarbini, Nadia; Streitberger, C.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/533590
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 139
  • ???jsp.display-item.citation.isi??? 126
social impact