Volatile and non-volatile organic acids present in sugar process juices were separated by ion-exclusion chromatography on an HPICE-AS1 cation-exchange column (H+ form) using both dilute hydrochloric acid and 2-propanol-water solutions of tridecafluoroheptanoic acid. Coupled with an anion-exchange micromembrane suppressor, a conductivity detector made it possible to reveal citric, tartaric, gluconic, malic, lactic, succinic, glycolic, formic, acetic and pyrrolidonecarboxylic acid in the presence of inorganic acids and non-ionic organic matter. In sugar process juices subjected to alkaline and/or oxidative treatment, increasing concentrations of the major acid components, i.e., acetic, formic and lactic acid, can be measured. The analysis is performed in the presence of sucrose and a simple clean-up by rapid batch treatment with a cation exchanger (H+ form) is sufficient to remove proteins and cations. The multiple standard addition procedure is used for calibration. © 1991.

Determination of volatile and non-volatile organic acids in technical sugar solutions by ion-exclusion chromatography

BLO, Gabriella
1991

Abstract

Volatile and non-volatile organic acids present in sugar process juices were separated by ion-exclusion chromatography on an HPICE-AS1 cation-exchange column (H+ form) using both dilute hydrochloric acid and 2-propanol-water solutions of tridecafluoroheptanoic acid. Coupled with an anion-exchange micromembrane suppressor, a conductivity detector made it possible to reveal citric, tartaric, gluconic, malic, lactic, succinic, glycolic, formic, acetic and pyrrolidonecarboxylic acid in the presence of inorganic acids and non-ionic organic matter. In sugar process juices subjected to alkaline and/or oxidative treatment, increasing concentrations of the major acid components, i.e., acetic, formic and lactic acid, can be measured. The analysis is performed in the presence of sucrose and a simple clean-up by rapid batch treatment with a cation exchanger (H+ form) is sufficient to remove proteins and cations. The multiple standard addition procedure is used for calibration. © 1991.
1991
Accorsi, Ca; Blo, Gabriella
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/460166
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 13
social impact