Purpose: To analyze differences in refractive outcome Δ (difference between postoperative and expected refractive error) and in anterior segment changes between cataract surgery patients and combined phacovitrectomy patients. We also aimed to provide a corrective formula allowing to minimise the refractive outcome Δ in combined surgery patients. Methods: Candidates for phacoemulsification and combined phacovitrectomy (respectively PHACO and COMBINED groups) were prospectively enrolled in two specialised centres. Patients underwent best corrected visual acuity (BCVA) assessment, ultra-high speed anterior segment optical coherence tomography (OCT), gonioscopy, retinal OCT, slit lamp examination and biometry at baseline, 6 weeks postoperatively and 3 months postoperatively. Results: No differences in refractive Δ, refractive error and anterior segment parameters were noted between PHACO and COMBINED group (109 and 110 patients respectively) at 6 weeks. At 3 months, COMBINED group showed a spherical equivalent of −0.29 ± 0.10 D versus −0.03 ± 0.15 D in PHACO group (p = 0.023). COMBINED group showed a significantly higher Crystalline Lens Rise (CLR), angle-to-angle (ATA) and anterior chamber width (ACW) and a significantly lower anterior chamber depth (ACD) and refractive Δ with all 4 considered formulas at 3 months. For IOL power lower than 15, a hyperopic shift was observed instead. Conclusions: Anterior segment OCT suggests anterior displacement of the effective lens position in patients undergoing phacovitrectomy. A corrective formula can be applied to IOL power calculation to minimize undesired refractive error.

Refractive outcome in combined phacovitrectomy: Anterior segment changes and corrective factor for IOL power calculation improvement

Kilian, Raphael;
2024

Abstract

Purpose: To analyze differences in refractive outcome Δ (difference between postoperative and expected refractive error) and in anterior segment changes between cataract surgery patients and combined phacovitrectomy patients. We also aimed to provide a corrective formula allowing to minimise the refractive outcome Δ in combined surgery patients. Methods: Candidates for phacoemulsification and combined phacovitrectomy (respectively PHACO and COMBINED groups) were prospectively enrolled in two specialised centres. Patients underwent best corrected visual acuity (BCVA) assessment, ultra-high speed anterior segment optical coherence tomography (OCT), gonioscopy, retinal OCT, slit lamp examination and biometry at baseline, 6 weeks postoperatively and 3 months postoperatively. Results: No differences in refractive Δ, refractive error and anterior segment parameters were noted between PHACO and COMBINED group (109 and 110 patients respectively) at 6 weeks. At 3 months, COMBINED group showed a spherical equivalent of −0.29 ± 0.10 D versus −0.03 ± 0.15 D in PHACO group (p = 0.023). COMBINED group showed a significantly higher Crystalline Lens Rise (CLR), angle-to-angle (ATA) and anterior chamber width (ACW) and a significantly lower anterior chamber depth (ACD) and refractive Δ with all 4 considered formulas at 3 months. For IOL power lower than 15, a hyperopic shift was observed instead. Conclusions: Anterior segment OCT suggests anterior displacement of the effective lens position in patients undergoing phacovitrectomy. A corrective formula can be applied to IOL power calculation to minimize undesired refractive error.
2024
Crincoli, Emanuele; Savastano, Alfonso; Ferrara, Silvia; Caporossi, Tomaso; Miere, Alexandra; Souied, Eric H; Savastano, Maria Cristina; Kilian, Rapha...espandi
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2602512
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact