Recent studies point out that water distribution networks can be affected by long- and short-term pressure oscillations due to the users' activity. However, these transients, generated at the household level, before reaching the water distribution network pass through, and thus affect, the water service line and can contribute to its deterioration. Despite the role of user-induced transients in stressing service lines, few studies in the literature explored the topic, exclusively by means of laboratory tests. The current study is aimed at exploring the effects of user's activity on a real service line starting from the field monitoring of pressure data at 500-Hz temporal resolution. Pressure signals are collected both when activating single water devices of the user supplied by the service line and during the ordinary use of domestic devices. The analyses of the acquired data highlight that the domestic service line is subjected to significant pressure variations (which can reach extreme values of −15 and +65 m) based on the device type and distance between the device and the service line and that the use of these devices can continuously stress the water service line.

Investigation of pressure transients induced on a real water service line by user’s activity

Marsili V.
Primo
;
Mazzoni F.;Alvisi S.;Meniconi S.;Brunone B.;Franchini M.
Ultimo
2023

Abstract

Recent studies point out that water distribution networks can be affected by long- and short-term pressure oscillations due to the users' activity. However, these transients, generated at the household level, before reaching the water distribution network pass through, and thus affect, the water service line and can contribute to its deterioration. Despite the role of user-induced transients in stressing service lines, few studies in the literature explored the topic, exclusively by means of laboratory tests. The current study is aimed at exploring the effects of user's activity on a real service line starting from the field monitoring of pressure data at 500-Hz temporal resolution. Pressure signals are collected both when activating single water devices of the user supplied by the service line and during the ordinary use of domestic devices. The analyses of the acquired data highlight that the domestic service line is subjected to significant pressure variations (which can reach extreme values of −15 and +65 m) based on the device type and distance between the device and the service line and that the use of these devices can continuously stress the water service line.
2023
Marsili, V.; Mazzoni, F.; Alvisi, S.; Maietta, F.; Capponi, C.; Meniconi, S.; Brunone, Bruno; Franchini, M.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2543850
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 6
social impact