Aims: Point-of-care ultrasound (POCUS) is the acquisition and interpretation of ultrasound imaging at the bedside to solve specific clinical questions based on signs and symptoms of presentation. While several studies evaluated POCUS diagnostic accuracy for a variety of clinical pictures in the emergency department (ED), only a few data are available on POCUS diagnostic accuracy performed by physicians with different POCUS skills. The objective of this research was to evaluate the diagnostic accuracy of POCUS compared to standard diagnostic imaging in the ED. Materials and methods: This was a retrospective study conducted in the ED of a third-level university hospital. Patients who underwent cardiac, thoracic, abdominal, or venous lower limb POCUS and a standard imaging examination between June 2021 and January 2022 were included. Results: 1047 patients were screened, and 844 patients included. A total of 933 POCUS was included (102, 12.09%, cardiac; 466, 55.21%, thoracic; 336, 39.8%, abdominal; 29, 3.44%, lower limb venous POCUS), accounting for 2029 examinations. POCUS demonstrated 96.6% (95% CI 95.72-97.34) accuracy, 47.73 (95% CI 33.64-67.72) +LR, 0.09 (95% CI 0.06-0.12) -LR. +LR was greater than 10 for all investigations but for hydronephrosis (5.8), and -LR never exceeded 0.4. Conclusions: POCUS exhibited high diagnostic accuracy for virtually all conditions when performed by emergency department physicians.

Diagnostic accuracy of Point Of Care UltraSound (POCUS) in clinical practice: A retrospective, emergency department based study

Michele Domenico Spampinato
Primo
;
Francesco Luppi
Secondo
;
Enrico Cristofaro;Marcello Benedetto;Antonella Cianci;Tommaso Bachechi;Caterina Ghirardi;Benedetta Perna;Matteo Guarino;Angelina Passaro;Roberto De Giorgio
Penultimo
;
2023

Abstract

Aims: Point-of-care ultrasound (POCUS) is the acquisition and interpretation of ultrasound imaging at the bedside to solve specific clinical questions based on signs and symptoms of presentation. While several studies evaluated POCUS diagnostic accuracy for a variety of clinical pictures in the emergency department (ED), only a few data are available on POCUS diagnostic accuracy performed by physicians with different POCUS skills. The objective of this research was to evaluate the diagnostic accuracy of POCUS compared to standard diagnostic imaging in the ED. Materials and methods: This was a retrospective study conducted in the ED of a third-level university hospital. Patients who underwent cardiac, thoracic, abdominal, or venous lower limb POCUS and a standard imaging examination between June 2021 and January 2022 were included. Results: 1047 patients were screened, and 844 patients included. A total of 933 POCUS was included (102, 12.09%, cardiac; 466, 55.21%, thoracic; 336, 39.8%, abdominal; 29, 3.44%, lower limb venous POCUS), accounting for 2029 examinations. POCUS demonstrated 96.6% (95% CI 95.72-97.34) accuracy, 47.73 (95% CI 33.64-67.72) +LR, 0.09 (95% CI 0.06-0.12) -LR. +LR was greater than 10 for all investigations but for hydronephrosis (5.8), and -LR never exceeded 0.4. Conclusions: POCUS exhibited high diagnostic accuracy for virtually all conditions when performed by emergency department physicians.
2023
Spampinato, MICHELE DOMENICO; Luppi, Francesco; Cristofaro, Enrico; Benedetto, Marcello; Cianci, Antonella; Bachechi, Tommaso; Ghirardi, Caterina; Perna, Benedetta; Guarino, Matteo; Passaro, Angelina; DE GIORGIO, Roberto; Sofia, Soccorsa
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2531852
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact