Purpose: To study the post-operative refractive error (RE) of patients undergoing combined phaco-vitrectomy and to find out which intraocular lens (IOL)-power formula had the best refractive outcomes. Methods: In this retrospective multicentric study we compared the preoperative expected target with the postoperative RE of patients undergoing combined phaco-vitrectomy due to vitreomacular traction, macular pucker, full thickness macular hole or lamellar macular hole. A multinomial logistic regression was performed to compare the postoperative REs and the differences between expected and postoperative REs among the SRK-T, Olsen's and Holladay-2 formulas. The correlation between the difference in REs and IOL-power was also studied. Results: Sixty-seven eyes with a mean axial length of 23.73 ± 1.21 mm were included. Forty-two (63%), 14 (21%) and 11 (16%) eyes were implanted with an IOL that was calculated respectively with SRK-T, Olsen's and the Holladay-2 formula. The mean preoperative expected- and post-operative REs were -0.16 ± 0.12D and -0.48 ± 0.17, respectively (p = 0.045). SRK-T and Holladay-2 formulas led to a significant myopic shift whereas Olsen's caused a significant hyperopic error, independently from the IOL power. Conclusion: Independently from the IOL power, none of the analyzed formulas is precise at calculating the post-operative RE.

Refractive error after combined phaco-vitrectomy: a multicentric study

Kilian, Raphael;
2023

Abstract

Purpose: To study the post-operative refractive error (RE) of patients undergoing combined phaco-vitrectomy and to find out which intraocular lens (IOL)-power formula had the best refractive outcomes. Methods: In this retrospective multicentric study we compared the preoperative expected target with the postoperative RE of patients undergoing combined phaco-vitrectomy due to vitreomacular traction, macular pucker, full thickness macular hole or lamellar macular hole. A multinomial logistic regression was performed to compare the postoperative REs and the differences between expected and postoperative REs among the SRK-T, Olsen's and Holladay-2 formulas. The correlation between the difference in REs and IOL-power was also studied. Results: Sixty-seven eyes with a mean axial length of 23.73 ± 1.21 mm were included. Forty-two (63%), 14 (21%) and 11 (16%) eyes were implanted with an IOL that was calculated respectively with SRK-T, Olsen's and the Holladay-2 formula. The mean preoperative expected- and post-operative REs were -0.16 ± 0.12D and -0.48 ± 0.17, respectively (p = 0.045). SRK-T and Holladay-2 formulas led to a significant myopic shift whereas Olsen's caused a significant hyperopic error, independently from the IOL power. Conclusion: Independently from the IOL power, none of the analyzed formulas is precise at calculating the post-operative RE.
2023
Kilian, Raphael; Crincoli, Emanuele; Rizzo, Clara; Ripa, Matteo; Faraldi, Francesco; Lavia, Carlo; Tartaro, Ruggero; Ceruti, Piero; Casini, Giamberto; Rizzo, Stanislao; Savastano, Alfonso
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2531460
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact