In spinal oncology traditional titanium implants could significantly impair evaluation of postoperative imaging because of artifacts, potentially affecting proper planning and execution of radiotherapy and adequate radiological follow-up to rule out progression of the disease. This is why carbon fiber reinforced (CFR)-PEEK implants have been developed for spinal fixation. The advantages of this system include fewer artifacts on imaging, potentially improving the execution and quality of radiotherapy, with also a reduced scattering effect to neighboring tissues. A comparative clinical and radiological study between new CFR-PEEK and standard titanium implants is described. Data recorded for each case included patient demographics, clinical, radiological and surgical data, intra- and postoperative complications, follow-up information. The goal of this study was to verify the safety and effectiveness of CFR-PEEK devices compared to standard titanium implants. A total number of 78 patients were reviewed. 36 patients underwent CFR-PEEK fixation, while titanium implants were used for 42 patients. Functional recovery was obtained in both groups and registered at last follow-up in terms of axial pain and neurological status. No significative differences were found between the two groups in terms of post-operative clinical complications and hardware-related complications. CFR-PEEK implants constitute a feasible and effective way to restore stability in metastatic spine tumors. This study found a non inferior favorable profile in terms of intraoperative and postoperative complications and functional recovery, compared to titanium. Further prospective studies are needed to clarify the potential oncological advantage of their radiolucency.

Carbon fiber reinforced vs titanium implants for fixation in spinal metastases: A comparative clinical study about safety and effectiveness of the new “carbon-strategy”

Monticelli M.;
2020

Abstract

In spinal oncology traditional titanium implants could significantly impair evaluation of postoperative imaging because of artifacts, potentially affecting proper planning and execution of radiotherapy and adequate radiological follow-up to rule out progression of the disease. This is why carbon fiber reinforced (CFR)-PEEK implants have been developed for spinal fixation. The advantages of this system include fewer artifacts on imaging, potentially improving the execution and quality of radiotherapy, with also a reduced scattering effect to neighboring tissues. A comparative clinical and radiological study between new CFR-PEEK and standard titanium implants is described. Data recorded for each case included patient demographics, clinical, radiological and surgical data, intra- and postoperative complications, follow-up information. The goal of this study was to verify the safety and effectiveness of CFR-PEEK devices compared to standard titanium implants. A total number of 78 patients were reviewed. 36 patients underwent CFR-PEEK fixation, while titanium implants were used for 42 patients. Functional recovery was obtained in both groups and registered at last follow-up in terms of axial pain and neurological status. No significative differences were found between the two groups in terms of post-operative clinical complications and hardware-related complications. CFR-PEEK implants constitute a feasible and effective way to restore stability in metastatic spine tumors. This study found a non inferior favorable profile in terms of intraoperative and postoperative complications and functional recovery, compared to titanium. Further prospective studies are needed to clarify the potential oncological advantage of their radiolucency.
2020
Cofano, F.; Di Perna, G.; Monticelli, M.; Marengo, N.; Ajello, M.; Mammi, M.; Vercelli, G.; Petrone, S.; Tartara, F.; Zenga, F.; Lanotte, M.; Garbossa...espandi
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2530871
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 44
  • ???jsp.display-item.citation.isi??? 39
social impact