: In the attempt to reduce the invasiveness of a transcrestal sinus floor elevation procedure, different aspects must be considered; that is, the minimization of intra- and postsurgery morbidity, the reduction of treatment time, and the simplification/elimination of the reconstructive technology. Within this context, a systematic literature search was performed for controlled clinical trials evaluating the impact of one or more of these aspects on transcrestal sinus floor elevation invasiveness. Nineteen articles (15 studies) were included. Overall, the results confirmed that transcrestal sinus floor elevation is a minimally invasive and effective option for bone augmentation in the edentulous, atrophic posterior maxilla. By using powered instruments rather than manual osteotomes and hand mallet, the invasiveness of transcrestal sinus floor elevation can be further reduced without affecting its clinical effectiveness. To impact effectively on morbidity, the key elements to consider when selecting instruments for transcrestal sinus floor elevation are (a) their availability as a standardized sequence, to be adapted on predetermined residual bone height, and (b) the possibility to control pressure (eg, with screwable osteotomes) and/or instrument excursion (eg, with stop devices) to fracture the maxillary sinus floor. Among powered instruments, a standardized sequence of drills incorporating a trephine drill seem to be particularly indicated, due to reduced chair time, high tolerability for the patient, and the possibility to isolate a bone core to implement histomorphometric outcomes. At molar extraction sites with an interradicular septum characterized by a height of at least 4 mm, immediate transcrestal sinus floor elevation and implant placement can be considered a valid option to shorten treatment time.

Minimal invasiveness in the transcrestal elevation of the maxillary sinus floor: A systematic review

Farina, Roberto
Primo
Conceptualization
;
Franzini, Chiara
Secondo
Data Curation
;
Trombelli, Leonardo
Penultimo
Supervision
;
Simonelli, Anna
Ultimo
Writing – Review & Editing
2023

Abstract

: In the attempt to reduce the invasiveness of a transcrestal sinus floor elevation procedure, different aspects must be considered; that is, the minimization of intra- and postsurgery morbidity, the reduction of treatment time, and the simplification/elimination of the reconstructive technology. Within this context, a systematic literature search was performed for controlled clinical trials evaluating the impact of one or more of these aspects on transcrestal sinus floor elevation invasiveness. Nineteen articles (15 studies) were included. Overall, the results confirmed that transcrestal sinus floor elevation is a minimally invasive and effective option for bone augmentation in the edentulous, atrophic posterior maxilla. By using powered instruments rather than manual osteotomes and hand mallet, the invasiveness of transcrestal sinus floor elevation can be further reduced without affecting its clinical effectiveness. To impact effectively on morbidity, the key elements to consider when selecting instruments for transcrestal sinus floor elevation are (a) their availability as a standardized sequence, to be adapted on predetermined residual bone height, and (b) the possibility to control pressure (eg, with screwable osteotomes) and/or instrument excursion (eg, with stop devices) to fracture the maxillary sinus floor. Among powered instruments, a standardized sequence of drills incorporating a trephine drill seem to be particularly indicated, due to reduced chair time, high tolerability for the patient, and the possibility to isolate a bone core to implement histomorphometric outcomes. At molar extraction sites with an interradicular septum characterized by a height of at least 4 mm, immediate transcrestal sinus floor elevation and implant placement can be considered a valid option to shorten treatment time.
2023
Farina, Roberto; Franzini, Chiara; Trombelli, Leonardo; Simonelli, Anna
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2524990
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 8
social impact