For various pituitary adenomas, it has been demonstrated that somatostatin receptor can be present. Pilot studies have shown that radio-indium labeled pentetreotide allows very good scintigraphic localization of somatostatin receptor-bearing cell masses. Recently, the presence of CgA in pituitary adenomas has also been demonstrated. MAb A11, raised against CgA, has been successfully used with a three-step ISG for the diagnosis of neuroendocrine tumors. Therefore the combined use of three-step ISG with MAb A11 and radiolabeled somatostatin can be useful in the diagnosis of pituitary adenomas. Twelve patients, 5 secreting (group A) and 7 nonsecreting (group B) pituitary adenomas, were enrolled in the study. All patients underwent three-step ISG, and, 2 wk later, scintigraphy with111In-labeled pentetreotide (Octreoscan). Three-step ISG consisted of iv injection of 1 mg of biotinylated MAb A11 (first step), followed by 10 mg of avidin (second step) and [99mTc]PnAO-biotin (third step). Tomographic imaging were acquired for three-step ISG and Octreoscan at 2 and 4 h after radiotracer injection, respectively. The results are the following: 2 patients of group A (secreting tumors) had a positive three-step ISG, whereas all the patients but one of the same group had a positive pentetreotide study; all the patients of group B (nonsecreting tumors) had a positive three-step ISG and 4 had a positive pentetreotide scintigraphy. These data suggest the utility of the combined use of these techniques for a better diagnosis of pituitary adenomas. © 1994 Humana Press Inc.

Combined use of111In-labeled pentetreotide and three-step immunoscintigraphy with antichromogranin a monoclonal antibody in the diagnosis of pituitary adenomas

Magnani, P.
Primo
;
Paganelli, G.;Colombo, P.;Faglia, G.;
1994

Abstract

For various pituitary adenomas, it has been demonstrated that somatostatin receptor can be present. Pilot studies have shown that radio-indium labeled pentetreotide allows very good scintigraphic localization of somatostatin receptor-bearing cell masses. Recently, the presence of CgA in pituitary adenomas has also been demonstrated. MAb A11, raised against CgA, has been successfully used with a three-step ISG for the diagnosis of neuroendocrine tumors. Therefore the combined use of three-step ISG with MAb A11 and radiolabeled somatostatin can be useful in the diagnosis of pituitary adenomas. Twelve patients, 5 secreting (group A) and 7 nonsecreting (group B) pituitary adenomas, were enrolled in the study. All patients underwent three-step ISG, and, 2 wk later, scintigraphy with111In-labeled pentetreotide (Octreoscan). Three-step ISG consisted of iv injection of 1 mg of biotinylated MAb A11 (first step), followed by 10 mg of avidin (second step) and [99mTc]PnAO-biotin (third step). Tomographic imaging were acquired for three-step ISG and Octreoscan at 2 and 4 h after radiotracer injection, respectively. The results are the following: 2 patients of group A (secreting tumors) had a positive three-step ISG, whereas all the patients but one of the same group had a positive pentetreotide study; all the patients of group B (nonsecreting tumors) had a positive three-step ISG and 4 had a positive pentetreotide scintigraphy. These data suggest the utility of the combined use of these techniques for a better diagnosis of pituitary adenomas. © 1994 Humana Press Inc.
1994
Magnani, P.; Paganelli, G.; Siccardi, A. G.; Songini, C.; Colombo, P.; Faglia, G.; Fazio, F.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2521492
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 9
social impact