Background: Little data exist on the relationship between total stent length (TSL) and cardiovascular outcomes at very-long follow-up in patients with ST-elevation myocardial infarction (STEMI) in the 2nd generation drug-eluting stents (DES) era. Aim: To analyze the relationship between TSL and 10-year target-lesion failure (TLF) in STEMI patients treated with percutaneous coronary intervention enrolled in the EXAMINATION-EXTEND. Methods: The EXAMINATION-EXTEND was an extended-follow-up study of the EXAMINATION trial, which randomized 1:1 STEMI patients to receive DES or bare metal stent (BMS). The primary endpoint was TLF, defined as a composite of target lesion revascularization (TLR), target vessel myocardial infarction (TVMI), or definite/probable stent thrombosis (ST). Relationship between stent length and TLF was evaluated in the whole study group in a multiple-adjusted Cox regression model with TSL as a quantitative variable. Subgroup analysis was also performed according to stent type, diameter, and overlap. Results: A total of 1,489 patients with a median TSL of 23 mm (Q1-Q318-35 mm) were included. TSL was associated with TLF at 10 years (adjusted HR per 5 mm increase of 1.07; 95% CI, 1.01-1.14; P = .02). This effect was mainly driven by TLR and was consistent regardless of stent type, diameter, or overlap. There was no significant relationship between TSL and TV-MI or ST. Conclusions: In STEMI patients, there is a direct relationship between TSL implanted in the culprit vessel and the risk of TLF at 10 years, mainly driven by TLR. The use of DES did not modify this association.

Relationship between stent length and very long-term target lesion failure following percutaneous coronary intervention for ST-elevation myocardial infarction in the drug-eluting stents era: insights from the EXAMINATION-EXTEND study

Campo, Gianluca;Biscaglia, Simone;
2023

Abstract

Background: Little data exist on the relationship between total stent length (TSL) and cardiovascular outcomes at very-long follow-up in patients with ST-elevation myocardial infarction (STEMI) in the 2nd generation drug-eluting stents (DES) era. Aim: To analyze the relationship between TSL and 10-year target-lesion failure (TLF) in STEMI patients treated with percutaneous coronary intervention enrolled in the EXAMINATION-EXTEND. Methods: The EXAMINATION-EXTEND was an extended-follow-up study of the EXAMINATION trial, which randomized 1:1 STEMI patients to receive DES or bare metal stent (BMS). The primary endpoint was TLF, defined as a composite of target lesion revascularization (TLR), target vessel myocardial infarction (TVMI), or definite/probable stent thrombosis (ST). Relationship between stent length and TLF was evaluated in the whole study group in a multiple-adjusted Cox regression model with TSL as a quantitative variable. Subgroup analysis was also performed according to stent type, diameter, and overlap. Results: A total of 1,489 patients with a median TSL of 23 mm (Q1-Q318-35 mm) were included. TSL was associated with TLF at 10 years (adjusted HR per 5 mm increase of 1.07; 95% CI, 1.01-1.14; P = .02). This effect was mainly driven by TLR and was consistent regardless of stent type, diameter, or overlap. There was no significant relationship between TSL and TV-MI or ST. Conclusions: In STEMI patients, there is a direct relationship between TSL implanted in the culprit vessel and the risk of TLF at 10 years, mainly driven by TLR. The use of DES did not modify this association.
2023
Bujak, Kamil; Vidal-Cales, Pablo; Gabani, Rami; Rinaldi, Riccardo; Gomez-Lara, Josep; Ortega-Paz, Luis; Jimenez-Diaz, Victor; Jimenez-Kockar, Marcelo; Jimenez-Quevedo, Pilar; Diletti, Roberto; Campo, Gianluca; Silvestro, Antonio; Maristany, Jaume; Flores, Xacobe; Oyarzabal, Loreto; De Miguel-Castro, Antonio; Iñiguez, Andrés; Nombela-Franco, Luis; Ielasi, Alfonso; Tespili, Maurizio; Lenzen, Mattie; Biscaglia, Simone; Al-Shaibani, Soheil; Romaguera, Rafael; Gomez-Hospital, Joan Antoni; Gasior, Mariusz; Serruys, Patrick W; Sabate, Manel; Brugaletta, Salvatore
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0002870323001412-main.pdf

solo gestori archivio

Tipologia: Full text (versione editoriale)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 1.98 MB
Formato Adobe PDF
1.98 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2520490
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact