Background: Routine processing of prostate biopsies requires conventional steps that usually take a few days. The aim of this study was to validate the use of fluorescence laser confocal microscopy (FCM) for real-time diagnostics. Methods: We prospectively tested images from prostate needle biopsies (75 images were evaluated by FCM and conventional slides). Two pathologists reviewed the images and assessed agreements between FCM versus conventional slides and between pathologists (κ-values). Interpretation was performed on digital images from the VivaScope 2500 confocal microscope (MAVIG GmbH, Munich, Germany; Caliber I.D., Rochester, NY, USA) placed in the urological operating room. Cancerous versus benign tissue was the primary focus, then the application of the grading system. Results: Cancer was diagnosed in 24 conventional slides (on 75 images) in which agreement among pathologists was high for both conventional (κ=0.96) and FMC (κ=0.84). 1/24 (4%) was ISUP/WHO grade group I, 12/24 (50%) II, 8/24 (33%) III, 2/24 (8%) IV and 1/24 (4%) grade V. Near perfect agreement was obtained for grades I, IV and V (κ=0.85). Grade III values achieved a moderate agreement (κ=0.55). The mean time for laser scanning was 9 minutes. For the remaining non-tumor images, agreement was nearly perfect (κ=0.81). Conclusions: We validated the use of FCM for real-time cancer detection in prostate biopsies.

Validation of real-time prostatic biopsies evaluation with fluorescence laser confocal microscopy

Gobbo, Stefano
Primo
;
2023

Abstract

Background: Routine processing of prostate biopsies requires conventional steps that usually take a few days. The aim of this study was to validate the use of fluorescence laser confocal microscopy (FCM) for real-time diagnostics. Methods: We prospectively tested images from prostate needle biopsies (75 images were evaluated by FCM and conventional slides). Two pathologists reviewed the images and assessed agreements between FCM versus conventional slides and between pathologists (κ-values). Interpretation was performed on digital images from the VivaScope 2500 confocal microscope (MAVIG GmbH, Munich, Germany; Caliber I.D., Rochester, NY, USA) placed in the urological operating room. Cancerous versus benign tissue was the primary focus, then the application of the grading system. Results: Cancer was diagnosed in 24 conventional slides (on 75 images) in which agreement among pathologists was high for both conventional (κ=0.96) and FMC (κ=0.84). 1/24 (4%) was ISUP/WHO grade group I, 12/24 (50%) II, 8/24 (33%) III, 2/24 (8%) IV and 1/24 (4%) grade V. Near perfect agreement was obtained for grades I, IV and V (κ=0.85). Grade III values achieved a moderate agreement (κ=0.55). The mean time for laser scanning was 9 minutes. For the remaining non-tumor images, agreement was nearly perfect (κ=0.81). Conclusions: We validated the use of FCM for real-time cancer detection in prostate biopsies.
2023
Gobbo, Stefano; Eccher, Albino; Gallina, Sebastian; D'Aietti, Damiano; Princiotta, Alessandro; Ditonno, Francesco; Tafuri, Alessandro; Cerruto, Maria ...espandi
File in questo prodotto:
File Dimensione Formato  
Minerva Urol Nephrol-5352_Proof in PDF_V1_2023-06-30.pdf

solo gestori archivio

Descrizione: Pre-print
Tipologia: Pre-print
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 873.32 kB
Formato Adobe PDF
873.32 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
R19Y2023N05A0577.pdf

accesso aperto

Descrizione: Full text editoriale
Tipologia: Full text (versione editoriale)
Licenza: PUBBLICO - Pubblico con Copyright
Dimensione 1.13 MB
Formato Adobe PDF
1.13 MB Adobe PDF Visualizza/Apri

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2519150
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact