The Mooney wall slip correction procedure is sometimes mandatory in the rheological characterization via capillary viscometry of certain complex fluids that have the tendency of slipping at solid walls. Besides making the measurement more complex, the Mooney procedure may give rise to measurement error amplification due to an imprecise knowledge of the capillary radius, even if the uncertainty is of the order of 0.01 mm. This error amplification may be so large that the result becomes grossly inaccurate, and in the worst case the procedure may even not produce a physically acceptable result. In this work a MATLAB-based software that can help researchers determine the maximum allowable inaccuracy on the capillary diameter that can yield feasible data for fluids characterization is devised. For best results, though, the user should know in advance the constitutive characteristics of the unknown fluid in an approximate sense.

A MATLAB-Based Software for Estimating Measurement Uncertainties in Capillary Viscometry

Malagutti L.
Primo
;
Mazzanti V.;Mollica F.
Ultimo
2022

Abstract

The Mooney wall slip correction procedure is sometimes mandatory in the rheological characterization via capillary viscometry of certain complex fluids that have the tendency of slipping at solid walls. Besides making the measurement more complex, the Mooney procedure may give rise to measurement error amplification due to an imprecise knowledge of the capillary radius, even if the uncertainty is of the order of 0.01 mm. This error amplification may be so large that the result becomes grossly inaccurate, and in the worst case the procedure may even not produce a physically acceptable result. In this work a MATLAB-based software that can help researchers determine the maximum allowable inaccuracy on the capillary diameter that can yield feasible data for fluids characterization is devised. For best results, though, the user should know in advance the constitutive characteristics of the unknown fluid in an approximate sense.
2022
measurement accuracy; Mooney procedure; power law fluid; wall slip
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2506293
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact