Performance of triple GEM prototypes in strong magnetic field has been evaluated by means of a muon beam at the H4 line of the SPS test area at CERN. Data have been reconstructed and analyzed offline with two reconstruction methods: the charge centroid and the micro-Time-Projection-Chamber exploiting the charge and the time measurement respectively. Depending on the combination of the particle incident angle and magnetic filed, there's always one of the two algorithms achieving a spatial resolution of 100-120 μm.
Triple GEM performance in magnetic field
Farinelli R.
;Garzia I.;Gramigna S.;
2019
Abstract
Performance of triple GEM prototypes in strong magnetic field has been evaluated by means of a muon beam at the H4 line of the SPS test area at CERN. Data have been reconstructed and analyzed offline with two reconstruction methods: the charge centroid and the micro-Time-Projection-Chamber exploiting the charge and the time measurement respectively. Depending on the combination of the particle incident angle and magnetic filed, there's always one of the two algorithms achieving a spatial resolution of 100-120 μm.File in questo prodotto:
Non ci sono file associati a questo prodotto.
I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.