: Nowadays, most medical-diagnostic, environmental monitoring, etc. devices employ sensors whose fabrication reproducibility and response repeatability assessment are crucial. The former consists of large-scale sensor manufacture through a standardized process with almost identical morphology and behavior, while the latter consists of giving the same response upon repeating the same stimulus. The thermo-activated chemoresistive sensors, which change their conductance by interacting with the molecules composing the surrounding gas, are currently employed in many devices: in particular, thick-film (SnTiNb)O2 nanosensors were demonstrated to be particularly suitable in the medical and biological fields. Therefore, a set of thirteen of them, randomly selected from the same screen-printing deposition, were laboratory tested, and the outcomes were statistically analyzed in order to assess their consistency. At first, the working temperature that maximized both the sensor sensitivity and response repeatability was identified. Then, the sensors were subjected to different gas concentrations and humidities at this optimal working temperature. It resulted in the (SnTiNb)O2 nanosensors detecting and discriminating CO concentrations as low as 1 ppm and at high humidity degrees (up to 40%) with high repeatability since the response relative standard error ranged from 0.8 to 3.3% for CO and from 3.6 to 5.4% for water vapor.

Reproducibility and Repeatability Tests on (SnTiNb)O2 Sensors in Detecting ppm-Concentrations of CO and Up to 40% of Humidity: A Statistical Approach

Astolfi, Michele
Primo
;
Rispoli, Giorgio
;
Gherardi, Sandro;Zonta, Giulia;Malagù, Cesare
Ultimo
2023

Abstract

: Nowadays, most medical-diagnostic, environmental monitoring, etc. devices employ sensors whose fabrication reproducibility and response repeatability assessment are crucial. The former consists of large-scale sensor manufacture through a standardized process with almost identical morphology and behavior, while the latter consists of giving the same response upon repeating the same stimulus. The thermo-activated chemoresistive sensors, which change their conductance by interacting with the molecules composing the surrounding gas, are currently employed in many devices: in particular, thick-film (SnTiNb)O2 nanosensors were demonstrated to be particularly suitable in the medical and biological fields. Therefore, a set of thirteen of them, randomly selected from the same screen-printing deposition, were laboratory tested, and the outcomes were statistically analyzed in order to assess their consistency. At first, the working temperature that maximized both the sensor sensitivity and response repeatability was identified. Then, the sensors were subjected to different gas concentrations and humidities at this optimal working temperature. It resulted in the (SnTiNb)O2 nanosensors detecting and discriminating CO concentrations as low as 1 ppm and at high humidity degrees (up to 40%) with high repeatability since the response relative standard error ranged from 0.8 to 3.3% for CO and from 3.6 to 5.4% for water vapor.
2023
Astolfi, Michele; Rispoli, Giorgio; Gherardi, Sandro; Zonta, Giulia; Malagù, Cesare
File in questo prodotto:
File Dimensione Formato  
sensors-23-01983.pdf

accesso aperto

Tipologia: Full text (versione editoriale)
Licenza: Creative commons
Dimensione 4.54 MB
Formato Adobe PDF
4.54 MB Adobe PDF Visualizza/Apri

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2504930
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact