Recurrent ventricular tachycardias impair patients’ quality of life significantly. This is caused by two factors – painful defibrillator discharges and the fear of them recurring. Currently available pharmacological and instrumental procedures are effective in 50% of patients on average. The so-called „bailout procedures“ are used in nonresponders, although the data supporting these are scarce. Stereotactic radiotherapy is one of them, being an innovative way of applying radiation beams not to tumour tissue, but to scar tissue in the heart muscle, which is often a cause of the recurrent ventricular tachycardia. Precisely targeted radiation application is of paramount importance for both efficiency and safety of this currently evolving technology. The main limit of the procedure is the accuracy of information transmitted from the electroanatomic mapping to the planning software of the irradiation device. To our knowledge, no method to convert substrate information into planning CT images has been developed so far.

Electroanatomic Mapping CT/MR Fusion Models for Stereotactic Radiotherapy Targeting in Ventricular Tachycardia Treatment

Proto A.;
2022

Abstract

Recurrent ventricular tachycardias impair patients’ quality of life significantly. This is caused by two factors – painful defibrillator discharges and the fear of them recurring. Currently available pharmacological and instrumental procedures are effective in 50% of patients on average. The so-called „bailout procedures“ are used in nonresponders, although the data supporting these are scarce. Stereotactic radiotherapy is one of them, being an innovative way of applying radiation beams not to tumour tissue, but to scar tissue in the heart muscle, which is often a cause of the recurrent ventricular tachycardia. Precisely targeted radiation application is of paramount importance for both efficiency and safety of this currently evolving technology. The main limit of the procedure is the accuracy of information transmitted from the electroanatomic mapping to the planning software of the irradiation device. To our knowledge, no method to convert substrate information into planning CT images has been developed so far.
2022
9781665492096
Ventricular tachycardia, radiofrequency ablation, stereotaxis, mapping, Cyberknife
File in questo prodotto:
File Dimensione Formato  
Electroanatomic Mapping CT_MR Fusion Models for Stereotactic Radiotherapy Targeting in Ventricular Tachycardia Treatment.pdf

solo gestori archivio

Descrizione: Full text editoriale
Tipologia: Full text (versione editoriale)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 555.52 kB
Formato Adobe PDF
555.52 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2503911
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact