The aim of the present study was to investigate outcomes of implantable cardioverter-defibrillator (ICD) treatment in patients with arrhythmogenic right ventricular cardiomyopathy (ARVC). We reviewed baseline/follow-up data of 15 consecutive ARVC patients (mean age 55 +/- 15 years) and 30 randomly drawn patients with coronary artery disease (CAD) (mean age 60 +/- 10 years) with matching durations of follow-up (all implanted with ICDs for primary/secondary prevention of sudden death). At implant, appropriate placement of the RV lead was more difficult in ARVC patients. During follow-up (median 41 months), appropriate interventions for any ventricular tachyarrhythmias occurred in 8 (53%) ARVC patients and 17 (57%) CAD patients, but the occurrence of high rate (>240 beats/min) ventricular tachyarrhythmias was higher in ARVC patients. Inappropriate ICD interventions occurred in 5 (33%) ARVC patients and 10 (33%) CAD patients. Lead-related adverse events requiring surgical revision occurred in 7 (47%) ARVC patients as compared with 4 (13%) CAD patients (P = 0.0004). While ICD implantation is highly effective for prevention of sudden death in ARVC, it does carry elevated burdens of long-term lead-related adverse events. These findings underline the need of careful follow-up in ARVC aimed at early recognition of complications that can impair ICD function.

Outcome of cardioverter-defibrillator implant in patients with arrhythmogenic right ventricular cardiomyopathy

BERTINI, MATTEO;RAPEZZI, CLAUDIO;
2007

Abstract

The aim of the present study was to investigate outcomes of implantable cardioverter-defibrillator (ICD) treatment in patients with arrhythmogenic right ventricular cardiomyopathy (ARVC). We reviewed baseline/follow-up data of 15 consecutive ARVC patients (mean age 55 +/- 15 years) and 30 randomly drawn patients with coronary artery disease (CAD) (mean age 60 +/- 10 years) with matching durations of follow-up (all implanted with ICDs for primary/secondary prevention of sudden death). At implant, appropriate placement of the RV lead was more difficult in ARVC patients. During follow-up (median 41 months), appropriate interventions for any ventricular tachyarrhythmias occurred in 8 (53%) ARVC patients and 17 (57%) CAD patients, but the occurrence of high rate (>240 beats/min) ventricular tachyarrhythmias was higher in ARVC patients. Inappropriate ICD interventions occurred in 5 (33%) ARVC patients and 10 (33%) CAD patients. Lead-related adverse events requiring surgical revision occurred in 7 (47%) ARVC patients as compared with 4 (13%) CAD patients (P = 0.0004). While ICD implantation is highly effective for prevention of sudden death in ARVC, it does carry elevated burdens of long-term lead-related adverse events. These findings underline the need of careful follow-up in ARVC aimed at early recognition of complications that can impair ICD function.
2007
Boriani, Giuseppe; P., Artale; Biffi, Mauro; Martignani, Cristian; Frabetti, Lorenzo; Valzania, Cinzia; Diemberger, Igor; Ziacchi, Matteo; Bertini, Matteo; Rapezzi, Claudio; Parlapiano, MARIO NICOLA; Branzi, Angelo
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2501019
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 32
  • ???jsp.display-item.citation.isi??? 28
social impact