This is a prospective interventional clinical study evaluating intraocular inflammation developed after Ultrasound Cyclo Plasty (UCP) for the treatment of glaucoma. Eighteen eyes of 18 patients were treated with UCP second-generation probes (Eye OP1). After treatment, the mean intraocular pressure (IOP) significantly decreased from 26.8±7.2 to 18.8±6.1 mm Hg at day 1 and to 14.7±3.4 mm Hg at month 6 (all P<0.001). Mean laser flare-cell photometry value steeply increased after surgery from 12.1±7.5 to 64.1±53.9 ph/ms (P=0.001) at day 1, and then progressively decreased to respectively 60.6±49.7 at day 7, 43.5±38.5 at day 14 and 28.2±18.3 at month 1 (all P<0.05), returning at levels similar to baseline ones at month 3 and month 6 (respectively 16.7±6.2 and 12.8±10.2, both P>0.05). A significant negative correlation was found between postoperative increase of aqueous flare values and anterior chamber depth (R=-0.568, P=0.014). This timeframe may be considered reasonable for repeating UCP treatment, when required.

Intraocular inflammation after Ultrasound Cyclo Plasty for the treatment of glaucoma

Pellegrini M
Co-primo
;
2019

Abstract

This is a prospective interventional clinical study evaluating intraocular inflammation developed after Ultrasound Cyclo Plasty (UCP) for the treatment of glaucoma. Eighteen eyes of 18 patients were treated with UCP second-generation probes (Eye OP1). After treatment, the mean intraocular pressure (IOP) significantly decreased from 26.8±7.2 to 18.8±6.1 mm Hg at day 1 and to 14.7±3.4 mm Hg at month 6 (all P<0.001). Mean laser flare-cell photometry value steeply increased after surgery from 12.1±7.5 to 64.1±53.9 ph/ms (P=0.001) at day 1, and then progressively decreased to respectively 60.6±49.7 at day 7, 43.5±38.5 at day 14 and 28.2±18.3 at month 1 (all P<0.05), returning at levels similar to baseline ones at month 3 and month 6 (respectively 16.7±6.2 and 12.8±10.2, both P>0.05). A significant negative correlation was found between postoperative increase of aqueous flare values and anterior chamber depth (R=-0.568, P=0.014). This timeframe may be considered reasonable for repeating UCP treatment, when required.
2019
Pellegrini, M; Sebastiani, S; Giannaccare, G; Campos, Ec
File in questo prodotto:
File Dimensione Formato  
ijo-12-02-338.pdf

accesso aperto

Descrizione: versione editoriale
Tipologia: Full text (versione editoriale)
Licenza: Creative commons
Dimensione 372.01 kB
Formato Adobe PDF
372.01 kB Adobe PDF Visualizza/Apri

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2500624
Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 16
social impact