COVID-19-related ARDS is characterized by severe hypoxemia with initially preserved lung compliance and impaired ventilation/perfusion (V̇/Q̇) matching. PEEP can increase end-expiratory lung volume, but its effect on V̇/Q̇ mismatch in COVID-19-related ARDS is not clear.
Heterogeneity of Ventilation/Perfusion Mismatch at Different Levels of PEEP and in Mechanical Phenotypes of COVID-19 ARDS
Scaramuzzo, GaetanoPrimo
;Fogagnolo, Alberto;Mauri, Tommaso;Mari, Matilde;Turrini, Cecilia;Montanaro, Federica;Volta, Carlo Alberto;Spadaro, Savino
Ultimo
2023
Abstract
COVID-19-related ARDS is characterized by severe hypoxemia with initially preserved lung compliance and impaired ventilation/perfusion (V̇/Q̇) matching. PEEP can increase end-expiratory lung volume, but its effect on V̇/Q̇ mismatch in COVID-19-related ARDS is not clear.File in questo prodotto: