In stage I cutaneous melanoma, biopsy of the first tumour-draining lymph node (sentinel node, SN) may replace routine elective lymph node dissection (ELND). The patent blue dye (PBD) technique has been shown to be an original method for the localization of the SN, but its sensitivity is sometimes unsatisfactory, depending on the basin where the SN is located. We compared three methods to locate the SN: intraoperative PBD mapping, lymphoscintigraphy (LS) with an aspecific tracer (colloid) and LS with a specific tracer (monoclonal antibody, MoAb). Fifty patients with cutaneous melanoma were enrolled in this study. The day before surgery LS was performed following an intradermal injection of 55 MBq technetium-99m-labelled HSA colloidal particles (25 patients: group A) or 220 MBq of 99mTc-F(ab')2 MoAb 225.28 S (25 patients: group B) around the site of the primary lesion. In group B an equal amount of tracer was injected, as a control, in the contralateral site. Early and delayed images were acquired with a gamma camera and SN(s) marked on the skin. In all 50 patients the PBD technique was also performed immediately before surgery. When a blue node was identified intraoperatively, its radioactivity level was measured with a gamma probe. In the absence of blue coloration, the probe alone was used to detect the SN. Lymphoscintigraphic visualization of SNs was possible in 50/50 patients (100%), a total of 73 SNs (38 in group A and 35 in group B) were found, distributed in 55 basins. Gamma probe detection (GPD) allowed the identification of SNs in 49/50 patients (98%), and 72 SNs in 54 basins were localized. By contrast, using PBD, SNs were stained only in 40/50 patients (50 SNs in 40 basins). A tumour-positive SN was histologically proven in 13 patients (26%). In group B, no increase uptake was observed in the seven positive SNs (6/25 patients) compared with the contralateral uninvolved nodes. In conclusion this study demonstrates that LS combined with GPD is a safe method for detecting SNs and is more sensitive than the PBD technique. The use of MoAb fragments did not show any advantage over the non-specific tracer.

Sentinel node localization in cutaneous melanoma: Lymphoscintigraphy with colloids and antibody fragments versus blue dye mapping

Paganelli, Giovanni
1998

Abstract

In stage I cutaneous melanoma, biopsy of the first tumour-draining lymph node (sentinel node, SN) may replace routine elective lymph node dissection (ELND). The patent blue dye (PBD) technique has been shown to be an original method for the localization of the SN, but its sensitivity is sometimes unsatisfactory, depending on the basin where the SN is located. We compared three methods to locate the SN: intraoperative PBD mapping, lymphoscintigraphy (LS) with an aspecific tracer (colloid) and LS with a specific tracer (monoclonal antibody, MoAb). Fifty patients with cutaneous melanoma were enrolled in this study. The day before surgery LS was performed following an intradermal injection of 55 MBq technetium-99m-labelled HSA colloidal particles (25 patients: group A) or 220 MBq of 99mTc-F(ab')2 MoAb 225.28 S (25 patients: group B) around the site of the primary lesion. In group B an equal amount of tracer was injected, as a control, in the contralateral site. Early and delayed images were acquired with a gamma camera and SN(s) marked on the skin. In all 50 patients the PBD technique was also performed immediately before surgery. When a blue node was identified intraoperatively, its radioactivity level was measured with a gamma probe. In the absence of blue coloration, the probe alone was used to detect the SN. Lymphoscintigraphic visualization of SNs was possible in 50/50 patients (100%), a total of 73 SNs (38 in group A and 35 in group B) were found, distributed in 55 basins. Gamma probe detection (GPD) allowed the identification of SNs in 49/50 patients (98%), and 72 SNs in 54 basins were localized. By contrast, using PBD, SNs were stained only in 40/50 patients (50 SNs in 40 basins). A tumour-positive SN was histologically proven in 13 patients (26%). In group B, no increase uptake was observed in the seven positive SNs (6/25 patients) compared with the contralateral uninvolved nodes. In conclusion this study demonstrates that LS combined with GPD is a safe method for detecting SNs and is more sensitive than the PBD technique. The use of MoAb fragments did not show any advantage over the non-specific tracer.
1998
Bartolomei, Mirco; Testori, Alessandro; Chinol, Marco; Gennari, Roberto; De Cicco, Concetta; Leonardi, Lorenzo; Zoboli, Stefania; Paganelli, Giovanni
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2496335
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 44
  • ???jsp.display-item.citation.isi??? 37
social impact