Gas turbine particle ingestion may lead to the deposition of contaminants in the compressor section, inducing the performance losses of the whole engine. The economic losses derived from this issue push great interest in the investigation of such a phenomenon from a numerical and experimental standpoint. This paper describes a quantitative approach to predict particle deposition on the vanes of an axial compressor starting from the flow field obtained employing CFD simulations. The results are then compared to the experiments performed on the Allison 250 C18 compressor unit subject to particle ingestion under controlled conditions. The results derived from the experimental and numerical investigations are presented, providing insight into the mass deposited on the vanes and the corresponding zones most affected by the particle deposition issue. The numerical model showed good agreement in the estimation of the predicted values of the deposited mass and the corresponding patterns through the compressor stages. The low-complexity approach proposed here, helps the designer to predict the contamination of the stationary rows starting from a simple set of single-phase numerical results. Furthermore, with the implementation of this approach into the design path, the designer could reduce the impact of fouling, looking at the effects of their solutions under the foulingreduction light.

A quantitative approach for the estimation of the fouling rate on the stationary parts of a multistage test compressor

Vulpio A.;Suman A.;Casari N.;Pinelli M.
2021

Abstract

Gas turbine particle ingestion may lead to the deposition of contaminants in the compressor section, inducing the performance losses of the whole engine. The economic losses derived from this issue push great interest in the investigation of such a phenomenon from a numerical and experimental standpoint. This paper describes a quantitative approach to predict particle deposition on the vanes of an axial compressor starting from the flow field obtained employing CFD simulations. The results are then compared to the experiments performed on the Allison 250 C18 compressor unit subject to particle ingestion under controlled conditions. The results derived from the experimental and numerical investigations are presented, providing insight into the mass deposited on the vanes and the corresponding zones most affected by the particle deposition issue. The numerical model showed good agreement in the estimation of the predicted values of the deposited mass and the corresponding patterns through the compressor stages. The low-complexity approach proposed here, helps the designer to predict the contamination of the stationary rows starting from a simple set of single-phase numerical results. Furthermore, with the implementation of this approach into the design path, the designer could reduce the impact of fouling, looking at the effects of their solutions under the foulingreduction light.
2021
978-0-7918-8501-7
fouling
multistage compressor
experimental and numerical investigations
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2477276
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? ND
social impact