Background: Quantitative flow ratio (QFR) is a tool for physiological lesion assessment based on invasive coronary angiography. Aims: We aimed to assess the reproducibility of QFR computed from the same angiograms as assessed by multiple observers from different, international sites. Methods: We included 50 patients previously enrolled in dedicated QFR studies. QFR was computed twice, one month apart by five blinded observers. The main analysis was the coefficient of variation (CV) as a measure of intra- and interobserver reproducibility. Key secondary analysis was identification of clinical and procedural characteristics predicting reproducibility. Results: The intraobserver CV ranged from 2.3% (1.5-2.8) to 10.2% (6.6-12.0) among the observers. The interobserver CV was 9.4% (8.0-10.5). The QFR observer, low angiographic quality, and low FFR were independent predictors of a large absolute difference between repeated QFR measurements defined as a difference larger than the median difference (>0.03). Conclusions: The inter- and intra-observer reproducibility for QFR computed from the same angiograms ranged from high to poor among multiple observers from different sites with an average agreement of 0.01±0.08 for repeated measurements. The reproducibility was dependent on the observer, angiographic quality and the coronary artery stenosis severity as assessed with FFR.

Reproducibility of Quantitative Flow Ratio: The QREP Study

Campo, Gianluca;Erriquez, Andrea;
2022

Abstract

Background: Quantitative flow ratio (QFR) is a tool for physiological lesion assessment based on invasive coronary angiography. Aims: We aimed to assess the reproducibility of QFR computed from the same angiograms as assessed by multiple observers from different, international sites. Methods: We included 50 patients previously enrolled in dedicated QFR studies. QFR was computed twice, one month apart by five blinded observers. The main analysis was the coefficient of variation (CV) as a measure of intra- and interobserver reproducibility. Key secondary analysis was identification of clinical and procedural characteristics predicting reproducibility. Results: The intraobserver CV ranged from 2.3% (1.5-2.8) to 10.2% (6.6-12.0) among the observers. The interobserver CV was 9.4% (8.0-10.5). The QFR observer, low angiographic quality, and low FFR were independent predictors of a large absolute difference between repeated QFR measurements defined as a difference larger than the median difference (>0.03). Conclusions: The inter- and intra-observer reproducibility for QFR computed from the same angiograms ranged from high to poor among multiple observers from different sites with an average agreement of 0.01±0.08 for repeated measurements. The reproducibility was dependent on the observer, angiographic quality and the coronary artery stenosis severity as assessed with FFR.
2022
Westra, Jelmer; Sejr-Hansen, Martin; Kołtowski, Łukasz; Mejía-Rentería, Hernán; Tu, Shengxian; Kochman, Janusz; Zhang, Yimin; Liu, Tommy; Campo, Gianl...espandi
File in questo prodotto:
File Dimensione Formato  
EIJ-D-21-00425_Westra.pdf

solo gestori archivio

Descrizione: versione editoriale
Tipologia: Full text (versione editoriale)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 465.5 kB
Formato Adobe PDF
465.5 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2472206
Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 24
social impact