The current narrative review provides an update of available knowledge on venous access techniques for cardiac implantable electronic device implantation, with a focus on axillary vein puncture. Lower procedure-related and lead-related complications have been reported with extrathoracic vein puncture techniques compared with intrathoracic accesses. In particular, extrathoracic lead access through the axillary vein seems to be associated with lower complication incidence than subclavian vein puncture and higher success rate than cephalic vein cutdown. In literature, many techniques have been described for axillary vein access. The use of contrast venography-guided puncture has facilitated the diffusion of the axillary vein approach for device implantation. Venography may be particularly useful in specific demographic and clinical device implantation contexts. Ultrasound-guided or microwire-guided vascular access for lead positioning can be considered a valid alternative to venography, although current applications for axillary vein puncture need further evaluations.
Axillary vein access for antiarrhythmic cardiac device implantation: a literature review
Biagio Sassone
Primo
Writing – Original Draft Preparation
;
2021
Abstract
The current narrative review provides an update of available knowledge on venous access techniques for cardiac implantable electronic device implantation, with a focus on axillary vein puncture. Lower procedure-related and lead-related complications have been reported with extrathoracic vein puncture techniques compared with intrathoracic accesses. In particular, extrathoracic lead access through the axillary vein seems to be associated with lower complication incidence than subclavian vein puncture and higher success rate than cephalic vein cutdown. In literature, many techniques have been described for axillary vein access. The use of contrast venography-guided puncture has facilitated the diffusion of the axillary vein approach for device implantation. Venography may be particularly useful in specific demographic and clinical device implantation contexts. Ultrasound-guided or microwire-guided vascular access for lead positioning can be considered a valid alternative to venography, although current applications for axillary vein puncture need further evaluations.File | Dimensione | Formato | |
---|---|---|---|
1.Sassone_JCM_2021_Axillary_vein_.pdf
solo gestori archivio
Descrizione: Full text editoriale
Tipologia:
Full text (versione editoriale)
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
677.17 kB
Formato
Adobe PDF
|
677.17 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.