Introduction: Osseointegration are often suffering from oral conditions, especially, the micro gap at the implant-abutment connection represents a site for bacterial plaque aggregation, leading to increased inflammatory cells and causing peri-implantitis. Aim: The aim of this narrative review was to describe the different kinds of implant-abutment connections and their ability to reduce bacterial leakage and thus prevent peri-implantitis. Materials and methods: The following databases were consulted: Pubmed, Scopus, Cochrane Library, and Research gate and a total of 528 articles were found. After reading the abstract and titles, 473 items were excluded. The remaining articles (n = 55) were assessed for full-text eligibility. Thirty-three studies were included in the review. Results and Conclusions: We selected 22 clinical trials and 11 reviews, examining a total sample of 2110 implants. From the review, it was clear that there exists a relationship between the implant-abutment interface and bacterial leakage. All the connections presented an amount of micro-gap and bacterial micro-leakage, though conical and mixed connection systems seemed to behave better. Moreover, both connections seemed to have a better load distribution and the mixed system also had anti-rotational properties which are very useful during the positioning of the prosthesis.

The impact of implant-abutment connection on clinical outcomes and microbial colonization: A narrative review

Lauritano D.
Primo
;
Carinci F.
Ultimo
2020

Abstract

Introduction: Osseointegration are often suffering from oral conditions, especially, the micro gap at the implant-abutment connection represents a site for bacterial plaque aggregation, leading to increased inflammatory cells and causing peri-implantitis. Aim: The aim of this narrative review was to describe the different kinds of implant-abutment connections and their ability to reduce bacterial leakage and thus prevent peri-implantitis. Materials and methods: The following databases were consulted: Pubmed, Scopus, Cochrane Library, and Research gate and a total of 528 articles were found. After reading the abstract and titles, 473 items were excluded. The remaining articles (n = 55) were assessed for full-text eligibility. Thirty-three studies were included in the review. Results and Conclusions: We selected 22 clinical trials and 11 reviews, examining a total sample of 2110 implants. From the review, it was clear that there exists a relationship between the implant-abutment interface and bacterial leakage. All the connections presented an amount of micro-gap and bacterial micro-leakage, though conical and mixed connection systems seemed to behave better. Moreover, both connections seemed to have a better load distribution and the mixed system also had anti-rotational properties which are very useful during the positioning of the prosthesis.
2020
Lauritano, D.; Moreo, G.; Lucchese, A.; Viganoni, C.; Limongelli, L.; Carinci, F.
File in questo prodotto:
File Dimensione Formato  
Lauritano et al. 2020 d.pdf

accesso aperto

Tipologia: Full text (versione editoriale)
Licenza: Creative commons
Dimensione 806.4 kB
Formato Adobe PDF
806.4 kB Adobe PDF Visualizza/Apri

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2434781
Citazioni
  • ???jsp.display-item.citation.pmc??? 21
  • Scopus 71
  • ???jsp.display-item.citation.isi??? 59
social impact