Despite the great progress in screening techniques and medical treatments, colorectal cancer remains one of the most widespread cancers in both sexes, with a high death rate. In this work, the volatile compounds released from human colon cancer tissues were detected by a set of four different chemoresistive sensors, made with a nanostructured powder of metal-oxide materials, inserted into an innovative patented device. The sensor responses to the exhalation of a primary cancer sample and of a healthy sample (both of the same weight, collected during colorectal surgery from the intestine of the same patient) were statistically analyzed. The sensors gave reversible, reproducible, and fast responses for at least one year of continuous use, making them quite superior in respect to the existing diagnostic methods. Preliminary results obtained using principal component analysis of the sensor responses to samples removed from 13 patients indicate that the nanostructured sensors employed in this study were able to distinguish between healthy and tumor tissue samples with coherent responses (the discrimination power of the most sensitive sensor was about 17%), highlighting a strong potential for clinical practice.

Colorectal cancer study with nanostructured sensors: Tumor marker screening of patient biopsies

Astolfi M.
Primo
;
Rispoli G.
Secondo
;
Anania G.;Nevoso V.;Artioli E.;Landini N.;Benedusi M.;Melloni E.;Secchiero P.;Tisato V.;Zonta G.
Penultimo
;
Malagu C.
Ultimo
2020

Abstract

Despite the great progress in screening techniques and medical treatments, colorectal cancer remains one of the most widespread cancers in both sexes, with a high death rate. In this work, the volatile compounds released from human colon cancer tissues were detected by a set of four different chemoresistive sensors, made with a nanostructured powder of metal-oxide materials, inserted into an innovative patented device. The sensor responses to the exhalation of a primary cancer sample and of a healthy sample (both of the same weight, collected during colorectal surgery from the intestine of the same patient) were statistically analyzed. The sensors gave reversible, reproducible, and fast responses for at least one year of continuous use, making them quite superior in respect to the existing diagnostic methods. Preliminary results obtained using principal component analysis of the sensor responses to samples removed from 13 patients indicate that the nanostructured sensors employed in this study were able to distinguish between healthy and tumor tissue samples with coherent responses (the discrimination power of the most sensitive sensor was about 17%), highlighting a strong potential for clinical practice.
2020
Astolfi, M.; Rispoli, G.; Anania, G.; Nevoso, V.; Artioli, E.; Landini, N.; Benedusi, M.; Melloni, E.; Secchiero, P.; Tisato, V.; Zonta, G.; Malagu, C.
File in questo prodotto:
File Dimensione Formato  
Astolfi M et al, 2020, nanomaterials-10-00606-v2.pdf

accesso aperto

Descrizione: Full text editoriale
Tipologia: Full text (versione editoriale)
Licenza: Creative commons
Dimensione 1.32 MB
Formato Adobe PDF
1.32 MB Adobe PDF Visualizza/Apri

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2422042
Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 10
social impact