Background Previous meta-analyses have investigated the relative safety and efficacy profiles of different types of drug-eluting stents (DES) and bare-metal stents (BMS); however, most prior trials in these meta-analyses reported follow-up to only 1 year, and as such, the relative long-term safety and efficacy of these devices are unknown. Many recent studies have now reported extended follow-up data. Objectives This study sought to investigate the long-term safety and efficacy of durable polymer-based DES, bioabsorbable polymer-based biolimus-eluting stents (BES), and BMS by means of network meta-analysis. Methods Randomized controlled trials comparing DES to each other or to BMS were searched through MEDLINE, EMBASE, and Cochrane databases and proceedings of international meetings. Information on study design, inclusion and exclusion criteria, sample characteristics, and clinical outcomes was extracted. Results Fifty-one trials that included a total of 52,158 randomized patients with follow-up duration ≥3 years were analyzed. At a median follow-up of 3.8 years, cobalt-chromium everolimus-eluting stents (EES) were associated with lower rates of mortality, definite stent thrombosis (ST), and myocardial infarction than BMS, paclitaxel-eluting stents (PES), and sirolimus-eluting stents (SES) and less ST than BES. Phosphorylcholine-based zotarolimus-eluting stents had lower rates of definite ST than SES and lower rates of myocardial infarction than BMS and PES. The late rates of target-vessel revascularization were reduced with all DES compared with BMS, with cobalt-chromium EES, platinum chromium-EES, SES, and BES also having lower target-vessel revascularization rates than PES. Conclusions After a median follow-up of 3.8 years, all DES demonstrated superior efficacy compared with BMS. Among DES, second-generation devices have substantially improved long-term safety and efficacy outcomes compared with first-generation devices.

Long-term safety of drug-eluting and bare-metal stents: Evidence from a comprehensive network meta-analysis

Rapezzi Claudio;
2015

Abstract

Background Previous meta-analyses have investigated the relative safety and efficacy profiles of different types of drug-eluting stents (DES) and bare-metal stents (BMS); however, most prior trials in these meta-analyses reported follow-up to only 1 year, and as such, the relative long-term safety and efficacy of these devices are unknown. Many recent studies have now reported extended follow-up data. Objectives This study sought to investigate the long-term safety and efficacy of durable polymer-based DES, bioabsorbable polymer-based biolimus-eluting stents (BES), and BMS by means of network meta-analysis. Methods Randomized controlled trials comparing DES to each other or to BMS were searched through MEDLINE, EMBASE, and Cochrane databases and proceedings of international meetings. Information on study design, inclusion and exclusion criteria, sample characteristics, and clinical outcomes was extracted. Results Fifty-one trials that included a total of 52,158 randomized patients with follow-up duration ≥3 years were analyzed. At a median follow-up of 3.8 years, cobalt-chromium everolimus-eluting stents (EES) were associated with lower rates of mortality, definite stent thrombosis (ST), and myocardial infarction than BMS, paclitaxel-eluting stents (PES), and sirolimus-eluting stents (SES) and less ST than BES. Phosphorylcholine-based zotarolimus-eluting stents had lower rates of definite ST than SES and lower rates of myocardial infarction than BMS and PES. The late rates of target-vessel revascularization were reduced with all DES compared with BMS, with cobalt-chromium EES, platinum chromium-EES, SES, and BES also having lower target-vessel revascularization rates than PES. Conclusions After a median follow-up of 3.8 years, all DES demonstrated superior efficacy compared with BMS. Among DES, second-generation devices have substantially improved long-term safety and efficacy outcomes compared with first-generation devices.
2015
Palmerini, Tullio; Benedetto, Umberto; Biondi-Zoccai, Giuseppe; Della Riva, Diego; Bacchi-Reggiani, Letizia; Smits Pieter, C.; Vlachojannis Georgios, J.; Jensen Lisette, Okkels; Christiansen Evald, H.; Berencsi, Klára; Valgimigli, Marco; Orlandi, Carlotta; Petrou, Mario; Rapezzi, Claudio; Stone Gregg, W.
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S073510971501918X-main.pdf

accesso aperto

Tipologia: Full text (versione editoriale)
Licenza: PUBBLICO - Pubblico con Copyright
Dimensione 889.48 kB
Formato Adobe PDF
889.48 kB Adobe PDF Visualizza/Apri

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2415452
Citazioni
  • ???jsp.display-item.citation.pmc??? 120
  • Scopus 396
  • ???jsp.display-item.citation.isi??? 372
social impact