Interventional cardiology procedures require full anticoagulation to prevent thrombus formation on catheters and devices with potential development of embolic complications. Bivalirudin, a short half-life direct thrombin inhibitor, has been largely used during percutaneous coronary interventions and represents the preferred alternative to heparin in patients with heparin-induced thrombocytopenia (HIT). However, few data are available about intraprocedural use of bivalirudin during transcatheter structural heart disease interventions. Activated clotting time (ACT) monitoring during bivalirudin infusion pre- sents some limitations and it is not mandatory. We report a case of bivalirudin use in a patient with type-2 HIT during percutaneous mitral valve repair with the Mitraclip system (Abbott, Abbott Park, Illinois, United States). Despite use of standard bivalirudin dose (0.75 mg/kg bolus and 1.4 mg/kg/min infusion—reduced infusion rate was motivated by a glomerular filtration rate of 37 mL/min), the patient developed a large thrombus on the second clip during its orientation toward the mitral orifice. ACT was measured at that time and was suboptimal (240 seconds). The case was successfully managed with clip and thrombus retrieval, adjunctive 0.3 mg/kg bivalirudin bolus and increased infusion rate, and clip repositioning with ACT monitoring. This report makes the case for mandatory ACT checking and drug titration during high-risk catheter–based structural heart disease interventions, even when thromboprophylaxis is performed with bivalirudin. Additional coagulation tests may be useful to monitor bivalirudin response in similar cases.

Antithrombotic Management during Percutaneous Mitral Valve Repair with the Mitraclip System in a Patient with Heparin-Induced Thrombocytopenia

Rapezzi Claudio
Ultimo
2018

Abstract

Interventional cardiology procedures require full anticoagulation to prevent thrombus formation on catheters and devices with potential development of embolic complications. Bivalirudin, a short half-life direct thrombin inhibitor, has been largely used during percutaneous coronary interventions and represents the preferred alternative to heparin in patients with heparin-induced thrombocytopenia (HIT). However, few data are available about intraprocedural use of bivalirudin during transcatheter structural heart disease interventions. Activated clotting time (ACT) monitoring during bivalirudin infusion pre- sents some limitations and it is not mandatory. We report a case of bivalirudin use in a patient with type-2 HIT during percutaneous mitral valve repair with the Mitraclip system (Abbott, Abbott Park, Illinois, United States). Despite use of standard bivalirudin dose (0.75 mg/kg bolus and 1.4 mg/kg/min infusion—reduced infusion rate was motivated by a glomerular filtration rate of 37 mL/min), the patient developed a large thrombus on the second clip during its orientation toward the mitral orifice. ACT was measured at that time and was suboptimal (240 seconds). The case was successfully managed with clip and thrombus retrieval, adjunctive 0.3 mg/kg bivalirudin bolus and increased infusion rate, and clip repositioning with ACT monitoring. This report makes the case for mandatory ACT checking and drug titration during high-risk catheter–based structural heart disease interventions, even when thromboprophylaxis is performed with bivalirudin. Additional coagulation tests may be useful to monitor bivalirudin response in similar cases.
2018
Saia, Francesco; Biagini, Elena; Berardini, Alessandra; Chiarabelli, Matteo; Bartolino, Emanuela; Compagnone, Miriam; Rapezzi, Claudio
File in questo prodotto:
File Dimensione Formato  
Antithrombotic.pdf

accesso aperto

Tipologia: Full text (versione editoriale)
Licenza: Creative commons
Dimensione 190.81 kB
Formato Adobe PDF
190.81 kB Adobe PDF Visualizza/Apri

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2414790
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact