We present a scanning device for 32-band multi-spectral imaging of paintings in the 380-800 nm spectral region. The system is based on contact-less and single-point measurement of the spectral reflectance factor. Multi-spectral images are obtained by scanning the painted surface under investigation. An adjustment procedure was established and calibration was performed by means of a set of seven matt ceramic color tiles certified by National Physical Laboratory (UK). Colorimetric calculations were carried out in the XYZ colorimetric space, by following the CIE recommendations and choosing the D65 standard illuminant and the 1931 standard observer.Measurement campaigns were carried out on several paintings in situ and at the INOA Optical Metrology Laboratory located inside the Opificio delle Pietre Dure in Florence. As an example we report herein on the measurements carried out on the Madonna in gloria tra Santi by Andrea Mantegna, (at present in the Pinacoteque of the Castello Sforzesco in Milan). Multivariate image analyses (MIA) were performed by considering the multi-spectral images as three-way data set. The stack of detected images were unfolded in a 2D data matrix and analyzed by the conventional Principal Component Analysis (PCA).

A scanning device for multi-spectral imaging of paintings

Bonifazzi C.
;
2006

Abstract

We present a scanning device for 32-band multi-spectral imaging of paintings in the 380-800 nm spectral region. The system is based on contact-less and single-point measurement of the spectral reflectance factor. Multi-spectral images are obtained by scanning the painted surface under investigation. An adjustment procedure was established and calibration was performed by means of a set of seven matt ceramic color tiles certified by National Physical Laboratory (UK). Colorimetric calculations were carried out in the XYZ colorimetric space, by following the CIE recommendations and choosing the D65 standard illuminant and the 1931 standard observer.Measurement campaigns were carried out on several paintings in situ and at the INOA Optical Metrology Laboratory located inside the Opificio delle Pietre Dure in Florence. As an example we report herein on the measurements carried out on the Madonna in gloria tra Santi by Andrea Mantegna, (at present in the Pinacoteque of the Castello Sforzesco in Milan). Multivariate image analyses (MIA) were performed by considering the multi-spectral images as three-way data set. The stack of detected images were unfolded in a 2D data matrix and analyzed by the conventional Principal Component Analysis (PCA).
2006
Colorimetric characterization; Multi-spectral imaging; Painting analysis; Scanning device; Spectral reflection factor
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2410302
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 1
social impact