This paper presents the study and analysis of URM-Buildings (Unreinforced Masonry Buildings), traditionally used in Albania. This typology was built in the 1980s to 1990s. Also these structures are designed with the Albanian design codes KTP-78. Building type 77/5 is selected to be analysed, since it is considered as the most problematic model from the building stock designed before the 1990s, based on its plan geometry. The focus will be on the Modal and the Static Non-linear Analysis Pushover of this 5-Storey building, based on Albanian spectral demand and capacity curves. In this work the peculiarities of the global response of URM-buildings are shown with the aid of a simplified non-linear element model, realized with AM Quake v6.0 software, able to reproduce earthquake damage to masonry buildings and failure modes observed in experimental tests. Among the different methods developed in the last years, this work will follow the inelastic (constant ductility) response spectrum method. The application of this method to Albanian URM-building typologies points out the difficulties related to existing masonry buildings; the methodology, developed for concrete structures, shows some problems when applied to URM structures in relation to the own characteristics of this structural system. Traditional masonry buildings have often very flexible diaphragms (in some cases made of wood) and this prevents from assumption of absolutely rigid floors. Furthermore, a different architectural disposition of walls may contribute to localize damage to ‘unexpected’ parts of building, due to irregularities in plan and elevation.

Ferrocement composites for strengthening of existing school structures in Albania

Nikolla Vesho
Co-primo
;
Aguljeln Marku
Secondo
2019

Abstract

This paper presents the study and analysis of URM-Buildings (Unreinforced Masonry Buildings), traditionally used in Albania. This typology was built in the 1980s to 1990s. Also these structures are designed with the Albanian design codes KTP-78. Building type 77/5 is selected to be analysed, since it is considered as the most problematic model from the building stock designed before the 1990s, based on its plan geometry. The focus will be on the Modal and the Static Non-linear Analysis Pushover of this 5-Storey building, based on Albanian spectral demand and capacity curves. In this work the peculiarities of the global response of URM-buildings are shown with the aid of a simplified non-linear element model, realized with AM Quake v6.0 software, able to reproduce earthquake damage to masonry buildings and failure modes observed in experimental tests. Among the different methods developed in the last years, this work will follow the inelastic (constant ductility) response spectrum method. The application of this method to Albanian URM-building typologies points out the difficulties related to existing masonry buildings; the methodology, developed for concrete structures, shows some problems when applied to URM structures in relation to the own characteristics of this structural system. Traditional masonry buildings have often very flexible diaphragms (in some cases made of wood) and this prevents from assumption of absolutely rigid floors. Furthermore, a different architectural disposition of walls may contribute to localize damage to ‘unexpected’ parts of building, due to irregularities in plan and elevation.
2019
Existing URM-Building, Static Nonlinear Analysis Pushover, Spectral demand, Seismic Performance, Constant ductility.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2408587
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact