ELI-NP-GBS is a high-brilliance gamma source that will produce monochromatic beams in the energy range 0.2–19.5 MeV through inverse Compton scattering. In order to obtain a monochromatic beam a collimation of the emission is necessary. Depending on the energy, the angular aperture required to provide the design bandwidth [Formula presented]E/E=0.5% is between 70 and 700 [Formula presented]rad. This collimation is provided by a stack of 14 tungsten slits, arranged with a relative rotation around the beam axis, so that the overlap will be a continuously adjustable aperture. To monitor the operation and alignment of the collimation, a set of detectors will provide a complete characterization of the gamma beam, including the measurement of the transverse spatial distribution. For this task a gamma beam profile imager based on a thin scintillator screen and a high-resolution CCD-camera was developed. In this work we briefly present the status of the collimation system and beam profile imager, which were designed, assembled and are currently under test at INFN-Ferrara laboratories.
Gamma beam collimation system and profile imager for ELI-NP
Cardarelli, P.
Primo
;Paternò, G.Secondo
;Di Domenico, G.;Marziani, M.;Gambaccini, M.;
2019
Abstract
ELI-NP-GBS is a high-brilliance gamma source that will produce monochromatic beams in the energy range 0.2–19.5 MeV through inverse Compton scattering. In order to obtain a monochromatic beam a collimation of the emission is necessary. Depending on the energy, the angular aperture required to provide the design bandwidth [Formula presented]E/E=0.5% is between 70 and 700 [Formula presented]rad. This collimation is provided by a stack of 14 tungsten slits, arranged with a relative rotation around the beam axis, so that the overlap will be a continuously adjustable aperture. To monitor the operation and alignment of the collimation, a set of detectors will provide a complete characterization of the gamma beam, including the measurement of the transverse spatial distribution. For this task a gamma beam profile imager based on a thin scintillator screen and a high-resolution CCD-camera was developed. In this work we briefly present the status of the collimation system and beam profile imager, which were designed, assembled and are currently under test at INFN-Ferrara laboratories.File | Dimensione | Formato | |
---|---|---|---|
1-s2.0-S0168900218313640-main.pdf
solo gestori archivio
Descrizione: versione editoriale
Tipologia:
Full text (versione editoriale)
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
859.74 kB
Formato
Adobe PDF
|
859.74 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.