ELI-NP-GBS is a high-brilliance gamma source that will produce monochromatic beams in the energy range 0.2–19.5 MeV through inverse Compton scattering. In order to obtain a monochromatic beam a collimation of the emission is necessary. Depending on the energy, the angular aperture required to provide the design bandwidth [Formula presented]E/E=0.5% is between 70 and 700 [Formula presented]rad. This collimation is provided by a stack of 14 tungsten slits, arranged with a relative rotation around the beam axis, so that the overlap will be a continuously adjustable aperture. To monitor the operation and alignment of the collimation, a set of detectors will provide a complete characterization of the gamma beam, including the measurement of the transverse spatial distribution. For this task a gamma beam profile imager based on a thin scintillator screen and a high-resolution CCD-camera was developed. In this work we briefly present the status of the collimation system and beam profile imager, which were designed, assembled and are currently under test at INFN-Ferrara laboratories.

Gamma beam collimation system and profile imager for ELI-NP

Cardarelli, P.
Primo
;
Paternò, G.
Secondo
;
Di Domenico, G.;Marziani, M.;Gambaccini, M.;
2019

Abstract

ELI-NP-GBS is a high-brilliance gamma source that will produce monochromatic beams in the energy range 0.2–19.5 MeV through inverse Compton scattering. In order to obtain a monochromatic beam a collimation of the emission is necessary. Depending on the energy, the angular aperture required to provide the design bandwidth [Formula presented]E/E=0.5% is between 70 and 700 [Formula presented]rad. This collimation is provided by a stack of 14 tungsten slits, arranged with a relative rotation around the beam axis, so that the overlap will be a continuously adjustable aperture. To monitor the operation and alignment of the collimation, a set of detectors will provide a complete characterization of the gamma beam, including the measurement of the transverse spatial distribution. For this task a gamma beam profile imager based on a thin scintillator screen and a high-resolution CCD-camera was developed. In this work we briefly present the status of the collimation system and beam profile imager, which were designed, assembled and are currently under test at INFN-Ferrara laboratories.
2019
Cardarelli, P.; Paternò, G.; Di Domenico, G.; Consoli, E.; Marziani, M.; Andreotti, M.; Evangelisti, F.; Squerzanti, S.; Gambaccini, M.; Albergo, S.; Cappello, G.; Tricomi, A.; Veltri, M.; Adriani, O.; Borgheresi, R.; Graziani, G.; Passaleva, G.; Serban, A.; Starodubtsev, O.; Variola, A.
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0168900218313640-main.pdf

solo gestori archivio

Descrizione: versione editoriale
Tipologia: Full text (versione editoriale)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 859.74 kB
Formato Adobe PDF
859.74 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2401007
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 4
social impact