Background: data from clinical experiences with Absorb bioresorbable scaffold (BRS) in STEMI raised concerns among clinicians about the device safety because a noteworthy scaffold thrombosis (ScT) rate was reported at early and long-term follow-up. Nevertheless, pre-specified technical suggestions of how to perform an optimal BRS procedure in STEMI were lacking. In this study we sought to assess the 1-year results following a pre-specified BRS implantation strategy in ST-elevation myocardial infarction (STEMI) patients undergoing primary PCI (pPCI). Methods: This is a prospective, multicenter study on 505 STEMI patients undergoing pPCI with Absorb following a dedicated implantation protocol. The primary end-point (a device oriented composite end-point (DOCE) of cardiac death, target-vessel myocardial infarction (TV-MI) and ischemia-driven target lesion revascularization (ID-TLR) within 30 days) was already reported. We here present DOCE, its singular components and ScT rates (secondary end-points) at 1-year. Results: According to the study protocol direct Absorb implantation was feasible in 47 (9.3%) patients while post-dilatation was performed in 468 (92.7%) cases. The hierarchical DOCE rate at 1-year was 1.2% (0.4% cardiac death, 0.4% TV-MI and 0.8% ID-TLR) versus 0.6% at 30-day. Two episodes (0.4%) of ScT (one probable subacute and one late definite) were reported. At 1-year, 99.2% patients were on dual antiplatelet therapy (95% with ticagrelor or prasugrel). Conclusions: A pre-specified Absorb implantation strategy in STEMI patients was associated with persistent low DOCE and ScT rates at 1-year. Longer term follow-up is needed to assess the role of this strategy on preventing very-late events (NCT02601781).

One-year results following a pre-specified ABSORB implantation strategy in ST-elevation myocardial infarction (BVS STEMI STRATEGY-IT study)

Campo, Gianluca
Secondo
;
2019

Abstract

Background: data from clinical experiences with Absorb bioresorbable scaffold (BRS) in STEMI raised concerns among clinicians about the device safety because a noteworthy scaffold thrombosis (ScT) rate was reported at early and long-term follow-up. Nevertheless, pre-specified technical suggestions of how to perform an optimal BRS procedure in STEMI were lacking. In this study we sought to assess the 1-year results following a pre-specified BRS implantation strategy in ST-elevation myocardial infarction (STEMI) patients undergoing primary PCI (pPCI). Methods: This is a prospective, multicenter study on 505 STEMI patients undergoing pPCI with Absorb following a dedicated implantation protocol. The primary end-point (a device oriented composite end-point (DOCE) of cardiac death, target-vessel myocardial infarction (TV-MI) and ischemia-driven target lesion revascularization (ID-TLR) within 30 days) was already reported. We here present DOCE, its singular components and ScT rates (secondary end-points) at 1-year. Results: According to the study protocol direct Absorb implantation was feasible in 47 (9.3%) patients while post-dilatation was performed in 468 (92.7%) cases. The hierarchical DOCE rate at 1-year was 1.2% (0.4% cardiac death, 0.4% TV-MI and 0.8% ID-TLR) versus 0.6% at 30-day. Two episodes (0.4%) of ScT (one probable subacute and one late definite) were reported. At 1-year, 99.2% patients were on dual antiplatelet therapy (95% with ticagrelor or prasugrel). Conclusions: A pre-specified Absorb implantation strategy in STEMI patients was associated with persistent low DOCE and ScT rates at 1-year. Longer term follow-up is needed to assess the role of this strategy on preventing very-late events (NCT02601781).
2019
Ielasi, Alfonso; Campo, Gianluca; Cortese, Bernardo; Leoncini, Massimo; Varricchio, Attilio; Brugaletta, Salvatore; Favaretto, Enrico; Fineschi, Massimo; Piraino, Davide; Calabria, Paolo; Granata, Francesco; Pisano, Francesco; Mussardo, Marco; Latib, Azeem; Tespili, Maurizio
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S1553838918304421-main.pdf

solo gestori archivio

Descrizione: Full text editoriale
Tipologia: Full text (versione editoriale)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 317.6 kB
Formato Adobe PDF
317.6 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2399383
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 6
social impact