Evaluation of the radioisotopic purity of technetium-99m (99mTc) produced in GBq amounts by proton bombardment of enriched molibdenum-100 (100Mo) metallic targets at low proton energies (i.e. Within 15-20 MeV) is conducted. This energy range was chosen since it is easily achievable by many conventional medical cyclotrons already available in the nuclear medicine departments of hospitals. The main motivation for such a study is in the framework of the research activities at the international level that have been conducted over the last few years to develop alternative production routes for the most widespread radioisotope used in medical imaging. The analysis of technetium isotopes and isomeric states (9xTc) present in the pertechnetate saline Na99mTcO4solutions, obtained after the extraction/purification procedure, reveals radionuclidic purity levels basically in compliance with the limits recently issued by European Pharmacopoeia 9.3 (2018 Sodium pertechnetate (99mTc) injection 4801-3). Moreover, the impact of9xTc contaminant nuclides on the final image quality is thoroughly evaluated, analyzing the emitted high-energy gamma rays and their influence on the image quality. The spatial resolution of images from cyclotron-produced99mTc acquired with a mini-gamma camera was determined and compared with that obtained using technetium-99m solutions eluted from standard99Mo/99mTc generators. The effect of the increased image background contribution due to Compton-scattered higher-energy gamma rays (Eγ> 200 keV), which could cause image-contrast deterioration, was also studied. It is concluded that, due to the high radionuclidic purity of cyclotron-produced99mTc using100Mo(p,2n)99mTc reaction at a proton beam energy in the range 15.7-19.4 MeV, the resulting image properties are well comparable with those from the generator-eluted99mTc.

Radioisotopic purity and imaging properties of cyclotron-produced 99mTc using direct100Mo(p,2n) reaction

Di Domenico G;Uccelli L;Boschi A;Taibi A;Duatti A;Martini P;Pasquali M;
2018

Abstract

Evaluation of the radioisotopic purity of technetium-99m (99mTc) produced in GBq amounts by proton bombardment of enriched molibdenum-100 (100Mo) metallic targets at low proton energies (i.e. Within 15-20 MeV) is conducted. This energy range was chosen since it is easily achievable by many conventional medical cyclotrons already available in the nuclear medicine departments of hospitals. The main motivation for such a study is in the framework of the research activities at the international level that have been conducted over the last few years to develop alternative production routes for the most widespread radioisotope used in medical imaging. The analysis of technetium isotopes and isomeric states (9xTc) present in the pertechnetate saline Na99mTcO4solutions, obtained after the extraction/purification procedure, reveals radionuclidic purity levels basically in compliance with the limits recently issued by European Pharmacopoeia 9.3 (2018 Sodium pertechnetate (99mTc) injection 4801-3). Moreover, the impact of9xTc contaminant nuclides on the final image quality is thoroughly evaluated, analyzing the emitted high-energy gamma rays and their influence on the image quality. The spatial resolution of images from cyclotron-produced99mTc acquired with a mini-gamma camera was determined and compared with that obtained using technetium-99m solutions eluted from standard99Mo/99mTc generators. The effect of the increased image background contribution due to Compton-scattered higher-energy gamma rays (Eγ> 200 keV), which could cause image-contrast deterioration, was also studied. It is concluded that, due to the high radionuclidic purity of cyclotron-produced99mTc using100Mo(p,2n)99mTc reaction at a proton beam energy in the range 15.7-19.4 MeV, the resulting image properties are well comparable with those from the generator-eluted99mTc.
2018
Uzunov, Nm; Melendez-Alafort, L; Bello, M; Cicoria, G; Zagni, F; De Nardo, L; Selva, A; Mou, L; Rossi-Alvarez, C; Pupillo, G; Di Domenico, G; Uccelli, L; Boschi, A; Groppi, F; Salvini, A; Taibi, A; Duatti, A; Martini, P; Pasquali, M; Loriggiola, M; Marengo, M; Strada, L; Manenti, S; Rosato, A; Esposito, J.
File in questo prodotto:
File Dimensione Formato  
Uzunov_Tc99m cyclotron RNP and Imaging properties_PMB_63_(2018).pdf

solo gestori archivio

Descrizione: versione editoriale
Tipologia: Full text (versione editoriale)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 2.6 MB
Formato Adobe PDF
2.6 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Radioisotopic Purity and imaging propert LAST.pdf

accesso aperto

Descrizione: post print
Tipologia: Post-print
Licenza: PUBBLICO - Pubblico con Copyright
Dimensione 1.56 MB
Formato Adobe PDF
1.56 MB Adobe PDF Visualizza/Apri

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2394282
Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 17
  • ???jsp.display-item.citation.isi??? 13
social impact