PURPOSE. To compare three microkeratome-assisted techniques for the preparation of ultrathin (UT) grafts for Descemet stripping automated endothelial keratoplasty. METHODS. After dissection with a 300-μm microkeratome head in 40 donor tissues, a second cut was performed with a 130-μm head either after manual stromal hydration (group A, n = 10) or osmotic hydration at the eye bank (group B, n = 10) or with a 50- or 90-μm head, depending on residual bed thickness (group C, n = 10); no further dissection was performed in the control group (group D, n =μ 10). Corneal thickness and endothelial cell (EC) count were determined at all appropriate stages. Statistical analysis was performed using a Fisher exact test. RESULTS. Final graft thicknesses in groups A (89.1 ± 34.1μm), B (84.1 ± 18.6 μm), and C (72.1 ± 10.1 μm) were significantly lower than in group D (201.9 ± 25.3 μm) (P < 0.001). EC loss did not differ significantly among the groups. Multiple areas of Descemet detachment were seen in 4 of 10 corneas of group A. CONCLUSIONS. All methods proved equally efficient in producing UT grafts, but stromal hydration induced tissue structural changes. EC loss was unaffected by the additional manipulation required to prepare UT grafts. © 2012 The Association for Research in Vision and Ophthalmology, Inc.

Microkeratome-assisted preparation of ultrathin grafts for descemet stripping automated endothelial keratoplasty

Busin, Massimo
;
2012

Abstract

PURPOSE. To compare three microkeratome-assisted techniques for the preparation of ultrathin (UT) grafts for Descemet stripping automated endothelial keratoplasty. METHODS. After dissection with a 300-μm microkeratome head in 40 donor tissues, a second cut was performed with a 130-μm head either after manual stromal hydration (group A, n = 10) or osmotic hydration at the eye bank (group B, n = 10) or with a 50- or 90-μm head, depending on residual bed thickness (group C, n = 10); no further dissection was performed in the control group (group D, n =μ 10). Corneal thickness and endothelial cell (EC) count were determined at all appropriate stages. Statistical analysis was performed using a Fisher exact test. RESULTS. Final graft thicknesses in groups A (89.1 ± 34.1μm), B (84.1 ± 18.6 μm), and C (72.1 ± 10.1 μm) were significantly lower than in group D (201.9 ± 25.3 μm) (P < 0.001). EC loss did not differ significantly among the groups. Multiple areas of Descemet detachment were seen in 4 of 10 corneas of group A. CONCLUSIONS. All methods proved equally efficient in producing UT grafts, but stromal hydration induced tissue structural changes. EC loss was unaffected by the additional manipulation required to prepare UT grafts. © 2012 The Association for Research in Vision and Ophthalmology, Inc.
2012
Busin, Massimo; Patel, Amit K.; Scorcia, Vincenzo; Ponzin, Diego
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2386996
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 22
  • Scopus 71
  • ???jsp.display-item.citation.isi??? 66
social impact