Focusing a hard x-ray beam would represent an innovative technique for tumour treatment, since such a beam may deliver a dose to a tumour located at a given depth under the skin, sparing the surrounding healthy cells. A detailed study of a focusing system for hard x-ray aimed at radiotherapy is presented here. Such a focusing system, named Laue lens, exploits x-ray diffraction and consists of a series of crystals disposed as concentric rings capable of concentrating a flux of x-rays towards a focusing point. A feasibility study regarding the positioning tolerances of the crystalline optical elements has been carried out. It is shown that a Laue lens can effectively be used in the context of radiotherapy for tumour treatments provided that the mounting errors are below certain values, which are reachable in the modern micromechanics. An extended survey based on an analytical approach and on simulations is presented for precisely estimating all the contributions of each mounting error, analysing their effect on the focal spot of the Laue lens. Finally, a simulation for evaluating the released dose in a water phantom is shown.

Laue lens for radiotherapy applications through a focused hard x-ray beam: A feasibility study on requirements and tolerances

Camattari, Riccardo
Primo
2017

Abstract

Focusing a hard x-ray beam would represent an innovative technique for tumour treatment, since such a beam may deliver a dose to a tumour located at a given depth under the skin, sparing the surrounding healthy cells. A detailed study of a focusing system for hard x-ray aimed at radiotherapy is presented here. Such a focusing system, named Laue lens, exploits x-ray diffraction and consists of a series of crystals disposed as concentric rings capable of concentrating a flux of x-rays towards a focusing point. A feasibility study regarding the positioning tolerances of the crystalline optical elements has been carried out. It is shown that a Laue lens can effectively be used in the context of radiotherapy for tumour treatments provided that the mounting errors are below certain values, which are reachable in the modern micromechanics. An extended survey based on an analytical approach and on simulations is presented for precisely estimating all the contributions of each mounting error, analysing their effect on the focal spot of the Laue lens. Finally, a simulation for evaluating the released dose in a water phantom is shown.
2017
Camattari, Riccardo
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2383430
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 5
social impact