PROBLEM: We have previously found that C1q is constitutively expressed by invading trophoblast and endothelial cells of decidua and contributes to vascular and tissue remodeling. Based on these findings, we sought to determine whether there were changes in the circulating level of C1q that may be used as a diagnostic and predictive marker of preeclampsia. METHOD OF STUDY: We measured the levels of C1q, C4, and complement activation products in serum or plasma of normal pregnant women and preeclamptic patients from different cohorts. RESULTS: We observed a marked decrease in the concentration of C1q associated with a reduced level of C4 in preeclamptic patients as compared to matched healthy pregnant woman but no significant difference in the circulating level of the activating products C5a and the soluble terminal complement complex sC5b-9. Analysis of serum samples collected at early phase of pregnancy from women who later developed preeclampsia failed to show a decrease in C1q level. CONCLUSION: The results of the present investigation demonstrate that low levels of C1q and C4 are associated with preeclampsia but cannot be used as predictive markers.

Complement component C1q as potential diagnostic but not predictive marker of preeclampsia

Celeghini, C.;
2016

Abstract

PROBLEM: We have previously found that C1q is constitutively expressed by invading trophoblast and endothelial cells of decidua and contributes to vascular and tissue remodeling. Based on these findings, we sought to determine whether there were changes in the circulating level of C1q that may be used as a diagnostic and predictive marker of preeclampsia. METHOD OF STUDY: We measured the levels of C1q, C4, and complement activation products in serum or plasma of normal pregnant women and preeclamptic patients from different cohorts. RESULTS: We observed a marked decrease in the concentration of C1q associated with a reduced level of C4 in preeclamptic patients as compared to matched healthy pregnant woman but no significant difference in the circulating level of the activating products C5a and the soluble terminal complement complex sC5b-9. Analysis of serum samples collected at early phase of pregnancy from women who later developed preeclampsia failed to show a decrease in C1q level. CONCLUSION: The results of the present investigation demonstrate that low levels of C1q and C4 are associated with preeclampsia but cannot be used as predictive markers.
2016
Agostinis, C.; Stampalija, T.; Tannetta, D.; Loganes, C.; Vecchi Brumatti, L.; De Seta, F.; Celeghini, C.; Radillo, O.; Sargent, I.; Tedesco, F.; Bull...espandi
File in questo prodotto:
File Dimensione Formato  
aji.12586.pdf

solo gestori archivio

Tipologia: Full text (versione editoriale)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 402.87 kB
Formato Adobe PDF
402.87 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2380344
Citazioni
  • ???jsp.display-item.citation.pmc??? 19
  • Scopus 36
  • ???jsp.display-item.citation.isi??? 33
social impact