The immune system of vertebrates “naturally” produces hypochlorous acid (HOCl) to fight against bacteria and pathogens. A patented electrochemical technology mirrors the above defense system, allowing the synthesis of HOCl solutions through the electrolysis of water enriched in salts, at the level of a few grams per liter. The system allows for the careful control of the pH of produced solutions, with consequent optimization of their activity. Once the HOCl is introduced into the water system, it is able to remove the biofilm from pipe network, significantly decreasing the level of Legionella colonization within 8–10 weeks from the beginning of the disinfection approach. The technology has been applied in a variety of healthcare facilities, both in Italy and in neighboring European countries. In the present paper, two successful case studies are briefly presented: Data were obtained from experiences in two different healthcare facilities, one in Italy and the other in Germany. Destruction of biofilm was indirectly testified by an increase of total organic carbon content of water; as a consequence, and because of the dosing of the disinfecting agent, some μg/L of total halomethanes were also formed. However, both compositional features were only observed during the initial stages of the disinfection treatment.
A modern approach to disinfection, as old as the evolution of vertebrates
FERRO, Sergio
2014
Abstract
The immune system of vertebrates “naturally” produces hypochlorous acid (HOCl) to fight against bacteria and pathogens. A patented electrochemical technology mirrors the above defense system, allowing the synthesis of HOCl solutions through the electrolysis of water enriched in salts, at the level of a few grams per liter. The system allows for the careful control of the pH of produced solutions, with consequent optimization of their activity. Once the HOCl is introduced into the water system, it is able to remove the biofilm from pipe network, significantly decreasing the level of Legionella colonization within 8–10 weeks from the beginning of the disinfection approach. The technology has been applied in a variety of healthcare facilities, both in Italy and in neighboring European countries. In the present paper, two successful case studies are briefly presented: Data were obtained from experiences in two different healthcare facilities, one in Italy and the other in Germany. Destruction of biofilm was indirectly testified by an increase of total organic carbon content of water; as a consequence, and because of the dosing of the disinfecting agent, some μg/L of total halomethanes were also formed. However, both compositional features were only observed during the initial stages of the disinfection treatment.I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.