The Church of the Nativity in Bethlehem has a narthex at the front that is as long as the façade of the Church and about six meters wide. Currently the narthex is covered by five cross vaults in a dangerous state of decay and is internally divided by three walls perpendicular to the façade, which appears to be strongly rotated outwards with a maximum horizontal top displacement of about 40 cm. Inside the central cross vault is heavily damaged and propped since the thirties of the last century. There have been numerous attempts over time to identify the causes of such a damage. Recent restoration works, still going on in the Church and in the narthex, made it possible to have a more precise insight into the construction features of the cross vaults, as a result of archival researches, in-situ inspections of the subsoil and a detailed laser scanner survey. All collected data allowed to put forward some hypotheses about the possible causes of the damage. This paper provides a scientific validation of these hypotheses through an advanced finite element numerical simulation which attempts to reproduce the evolution of the damage up to a deformed configuration quite close to the real one, starting from a three-dimensional simplified and undeformed model of the narthex. Such a model is then discretized by means of tetrahedron elements obeying a damage plasticity law which exhibits a softening behavior in both tension and compression. The numerical simulations provide some results that fit reasonably with the actual deformed configuration and can be considered as a useful tool for further insights.

Nativity Church Narthex: A non-linear FEM Procedure for the diagnosis of a structural damage

ALESSANDRI, Claudio
Ultimo
2016

Abstract

The Church of the Nativity in Bethlehem has a narthex at the front that is as long as the façade of the Church and about six meters wide. Currently the narthex is covered by five cross vaults in a dangerous state of decay and is internally divided by three walls perpendicular to the façade, which appears to be strongly rotated outwards with a maximum horizontal top displacement of about 40 cm. Inside the central cross vault is heavily damaged and propped since the thirties of the last century. There have been numerous attempts over time to identify the causes of such a damage. Recent restoration works, still going on in the Church and in the narthex, made it possible to have a more precise insight into the construction features of the cross vaults, as a result of archival researches, in-situ inspections of the subsoil and a detailed laser scanner survey. All collected data allowed to put forward some hypotheses about the possible causes of the damage. This paper provides a scientific validation of these hypotheses through an advanced finite element numerical simulation which attempts to reproduce the evolution of the damage up to a deformed configuration quite close to the real one, starting from a three-dimensional simplified and undeformed model of the narthex. Such a model is then discretized by means of tetrahedron elements obeying a damage plasticity law which exhibits a softening behavior in both tension and compression. The numerical simulations provide some results that fit reasonably with the actual deformed configuration and can be considered as a useful tool for further insights.
2016
978-1-138-02951-4
MASONRY CROSS VAULTS, FINITE ELEMENT SIMULATION, NATIVITY CHURCH
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2357630
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact