As part of an EC funded project, the design for a new phantom has been proposed that consists of a smaller contrast-detail part than the CDMAM phantom and that contains items for other parts of an acceptance protocol for digital mammography. A first prototype of the "DIGIMAM" has been produced. Both the CDMAM phantom and the DIGIMAM phantom were then used on a series of systems and read out as a part of a multi centre study. The results with the new phantom were very similar to results obtained with the CDMAM phantom: readers scored different from each other and there was an overlap in the scores for the different systems, A system with a poor score in CDMAM had also the worst score for DIGIMAM. Reading time was significantly reduced however. There was promising agreement between automated reading of CDMAM and the scores of the DIGIMAM phantom. In order to reduce the subjectivity of the readings, computerized reading of the DIGIMAM should be developed. In a second version of the phantom, we propose to add more disks of the same size and contrast in each square to improve the statistical power of each reading.

First validation of a new phantom for global quality control in digital mammography

TAIBI, Angelo;
2006

Abstract

As part of an EC funded project, the design for a new phantom has been proposed that consists of a smaller contrast-detail part than the CDMAM phantom and that contains items for other parts of an acceptance protocol for digital mammography. A first prototype of the "DIGIMAM" has been produced. Both the CDMAM phantom and the DIGIMAM phantom were then used on a series of systems and read out as a part of a multi centre study. The results with the new phantom were very similar to results obtained with the CDMAM phantom: readers scored different from each other and there was an overlap in the scores for the different systems, A system with a poor score in CDMAM had also the worst score for DIGIMAM. Reading time was significantly reduced however. There was promising agreement between automated reading of CDMAM and the scores of the DIGIMAM phantom. In order to reduce the subjectivity of the readings, computerized reading of the DIGIMAM should be developed. In a second version of the phantom, we propose to add more disks of the same size and contrast in each square to improve the statistical power of each reading.
2006
0819464252
0819464252
Contrast detail; Digital mammography; Quality assurance; Test object; Engineering (all)
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2355850
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact