The design and fabrication of a fully-automated, remotely controlled module for the extraction and purification of technetium-99m (Tc-99m), produced by proton bombardment of enriched Mo-100 molybdenum metallic targets in a low-energy medical cyclotron, is here described. After dissolution of the irradiated solid target in hydrogen peroxide, Tc-99m was obtained under the chemical form of 99mTcO4-, in high radionuclidic and radiochemical purity, by solvent extraction with methyl ethyl ketone (MEK). The extraction process was accomplished inside a glass column-shaped vial especially designed to allow for an easy automation of the whole procedure. Recovery yields were always >90% of the loaded activity. The final pertechnetate saline solution Na99mTcO4, purified using the automated module here described, is within the Pharmacopoeia quality control parameters and is therefore a valid alternative to generator-produced 99mTc. The resulting automated module is cost-effective and easily replicable for in-house production of high-purity Tc-99m by cyclotrons
A solvent-extraction module for cyclotron production of high-purity technetium-99m
MARTINI, Petra
Primo
;BOSCHI, Alessandra
Secondo
;UCCELLI, Licia;PASQUALI, Micol;DUATTI, Adriano;
2016
Abstract
The design and fabrication of a fully-automated, remotely controlled module for the extraction and purification of technetium-99m (Tc-99m), produced by proton bombardment of enriched Mo-100 molybdenum metallic targets in a low-energy medical cyclotron, is here described. After dissolution of the irradiated solid target in hydrogen peroxide, Tc-99m was obtained under the chemical form of 99mTcO4-, in high radionuclidic and radiochemical purity, by solvent extraction with methyl ethyl ketone (MEK). The extraction process was accomplished inside a glass column-shaped vial especially designed to allow for an easy automation of the whole procedure. Recovery yields were always >90% of the loaded activity. The final pertechnetate saline solution Na99mTcO4, purified using the automated module here described, is within the Pharmacopoeia quality control parameters and is therefore a valid alternative to generator-produced 99mTc. The resulting automated module is cost-effective and easily replicable for in-house production of high-purity Tc-99m by cyclotronsFile | Dimensione | Formato | |
---|---|---|---|
a solvent extraction module.pdf
solo gestori archivio
Descrizione: versione editoriale
Tipologia:
Full text (versione editoriale)
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
446.68 kB
Formato
Adobe PDF
|
446.68 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
UCCELLI_11392_2355709_preprint.pdf
accesso aperto
Descrizione: pre print
Tipologia:
Pre-print
Licenza:
PUBBLICO - Pubblico con Copyright
Dimensione
1.56 MB
Formato
Adobe PDF
|
1.56 MB | Adobe PDF | Visualizza/Apri |
11392 2355709_post-print_Duatti_Adriano.pdf
accesso aperto
Descrizione: post print
Tipologia:
Post-print
Licenza:
Creative commons
Dimensione
1.02 MB
Formato
Adobe PDF
|
1.02 MB | Adobe PDF | Visualizza/Apri |
I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.