Background: Atrial fibrillation (AF) can be treated with percutaneous catheter ablation procedures into the left atrium. Pulmonary veins stenosis (PV) stenosis is a severe complication of this procedure. Case presentation: we report a case of late hemoptysis secondary to severe PV stenosis in a man who underwent AF ablation 9 months before onset of symptoms. He presented four episodes of bleeding and developed an acute respiratory failure (ARF). Parameters of respiratory mechanics and medical investigation did not show any abnormalities. Only computed tomography (CT) angiography showed stenosis of 3 out of 4 native PVs. PV balloon dilatation in all affected PVs and a stent was implanted in 1 of the 3 PVs with full restoration of respiratory function during 1 year follow-up. Conclusion: PV stenosis may be the underlying cause of recurrent haemoptysis after AF ablation in the presence of normal respiratory parameters. This diagnosis can be confirmed by means of CT angiography and magnetic resonance imaging can provide accurate localization of stenosis.

An unusual case of acute respiratory failure in a patient with pulmonary veins stenosis late after catheter ablation of atrial fibrillation: A case report and the review of the literature

SPADARO, Savino
Primo
;
Bertini, Matteo;GALEOTTI, Roberto;VOLTA, Carlo Alberto
Ultimo
2015

Abstract

Background: Atrial fibrillation (AF) can be treated with percutaneous catheter ablation procedures into the left atrium. Pulmonary veins stenosis (PV) stenosis is a severe complication of this procedure. Case presentation: we report a case of late hemoptysis secondary to severe PV stenosis in a man who underwent AF ablation 9 months before onset of symptoms. He presented four episodes of bleeding and developed an acute respiratory failure (ARF). Parameters of respiratory mechanics and medical investigation did not show any abnormalities. Only computed tomography (CT) angiography showed stenosis of 3 out of 4 native PVs. PV balloon dilatation in all affected PVs and a stent was implanted in 1 of the 3 PVs with full restoration of respiratory function during 1 year follow-up. Conclusion: PV stenosis may be the underlying cause of recurrent haemoptysis after AF ablation in the presence of normal respiratory parameters. This diagnosis can be confirmed by means of CT angiography and magnetic resonance imaging can provide accurate localization of stenosis.
2015
Spadaro, Savino; Saturni, Sara; Cadorin, Delia; Colamussi, Maria V.; Bertini, Matteo; Galeotti, Roberto; Cappato, Riccardo; Ravenna, Franco; Volta, Carlo Alberto
File in questo prodotto:
File Dimensione Formato  
An unusual case 2015 BMC Pulm Med.pdf

accesso aperto

Tipologia: Full text (versione editoriale)
Licenza: Creative commons
Dimensione 2.08 MB
Formato Adobe PDF
2.08 MB Adobe PDF Visualizza/Apri

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2349539
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 7
social impact