The purpose of the work described here was to investigate the feasibility of assessing the jugular venous pulse (JVP) using ultrasound (US) equipment. Three young healthy subjects underwent a B-mode US scan of the internal jugular vein (IJV) to acquire a sonogram sequence in the transverse plane. On each acquired sonogram, the IJV contour was manually traced, and both the cross-sectional area (CSA) and the perimeter were measured. The CSA data set represents the US jugular diagram (USJD). The arterial distension waveform of the subjects was compared with its USJD. The correlation between the CSA and the perimeter was assessed during the cardiac cycle to verify IJV distension. For each subject, a short sonogram sequence of a few seconds was recorded, and the USJD obtained exhibited periodic behavior. Furthermore, for all subjects, the CSA was found to be correlated with the perimeter (Pearson coefficient, R > 0.9), indicating that the IJV in supine position is distended. We compared 390 manually traced contours of the IJV cross-sectional area with corresponding values semi-automatically calculated by an algorithm developed in-house. For all subjects, the sensitivity, specificity and accuracy were around 95%, 85% and 90% respectively. We found that a diagram reflecting the JVP can be obtained by analyzing a B-mode sonogram sequence of the IJV; such a diagram can result in a new methodology to assess the IJV functionality.
An ultrasonographic technique to assess the jugular venous pulse: A proof of concept
SISINI, Francesco
Primo
;TESSARI, Mirko;GADDA, Giacomo;DI DOMENICO, Giovanni;TAIBI, Angelo;MENEGATTI, Erica;GAMBACCINI, Mauro;ZAMBONI, PaoloUltimo
2015
Abstract
The purpose of the work described here was to investigate the feasibility of assessing the jugular venous pulse (JVP) using ultrasound (US) equipment. Three young healthy subjects underwent a B-mode US scan of the internal jugular vein (IJV) to acquire a sonogram sequence in the transverse plane. On each acquired sonogram, the IJV contour was manually traced, and both the cross-sectional area (CSA) and the perimeter were measured. The CSA data set represents the US jugular diagram (USJD). The arterial distension waveform of the subjects was compared with its USJD. The correlation between the CSA and the perimeter was assessed during the cardiac cycle to verify IJV distension. For each subject, a short sonogram sequence of a few seconds was recorded, and the USJD obtained exhibited periodic behavior. Furthermore, for all subjects, the CSA was found to be correlated with the perimeter (Pearson coefficient, R > 0.9), indicating that the IJV in supine position is distended. We compared 390 manually traced contours of the IJV cross-sectional area with corresponding values semi-automatically calculated by an algorithm developed in-house. For all subjects, the sensitivity, specificity and accuracy were around 95%, 85% and 90% respectively. We found that a diagram reflecting the JVP can be obtained by analyzing a B-mode sonogram sequence of the IJV; such a diagram can result in a new methodology to assess the IJV functionality.File | Dimensione | Formato | |
---|---|---|---|
sisini2015.pdf
solo gestori archivio
Descrizione: Editoriale first on line
Tipologia:
Full text (versione editoriale)
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
495.78 kB
Formato
Adobe PDF
|
495.78 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.