A technique is described for measuring pressure within the amniotic cavity and within fetal vessels and/or body compartments. Two saline‐filled catheters were connected at one end to needles inserted during indicated invasive procedures and at the other to silicon strain gauge transducers. In 36 pregnancies with normal liquor volume, stable intra‐amniotic pressure (IAP, range 1–14 mmHg) increased with gestation (r=0·48, p<0·01). In pregnancies complicated by severe oligohydramnios, IAP was ≤ 1 mm Hg and rose to normal levels with saline amnioinfusion. Raised IAP (range 17–26 mm Hg), found in pregnancies with gross polyhydramnios, fell with drainage of amniotic fluid. Subtraction manometry was used to determine supra‐amniotic pressure within the intervillus space, umbilical vein, umbilical artery, abdominal and thoracic cavities, and the urinary tract in normal and/or pathological fetuses. Low intravesical and intrapelvicalyceal pressures (median 6·5, range 2–10 mmHg) were noted in fetuses with obstructive uropathies. Intrauterine subtraction manometry appears to be a useful tool in the understanding of fetal pathophysiology and may be of clinical benefit in the therapeutic drainage and infusion of amniotic fluid and in the assessment of certain fetal disease states. Copyright © 1989 John Wiley & Sons, Ltd.

Intrauterine manometry: technique and application to fetal pathology

GRECO, Pantaleo;
1989

Abstract

A technique is described for measuring pressure within the amniotic cavity and within fetal vessels and/or body compartments. Two saline‐filled catheters were connected at one end to needles inserted during indicated invasive procedures and at the other to silicon strain gauge transducers. In 36 pregnancies with normal liquor volume, stable intra‐amniotic pressure (IAP, range 1–14 mmHg) increased with gestation (r=0·48, p<0·01). In pregnancies complicated by severe oligohydramnios, IAP was ≤ 1 mm Hg and rose to normal levels with saline amnioinfusion. Raised IAP (range 17–26 mm Hg), found in pregnancies with gross polyhydramnios, fell with drainage of amniotic fluid. Subtraction manometry was used to determine supra‐amniotic pressure within the intervillus space, umbilical vein, umbilical artery, abdominal and thoracic cavities, and the urinary tract in normal and/or pathological fetuses. Low intravesical and intrapelvicalyceal pressures (median 6·5, range 2–10 mmHg) were noted in fetuses with obstructive uropathies. Intrauterine subtraction manometry appears to be a useful tool in the understanding of fetal pathophysiology and may be of clinical benefit in the therapeutic drainage and infusion of amniotic fluid and in the assessment of certain fetal disease states. Copyright © 1989 John Wiley & Sons, Ltd.
1989
Nicolini, U; Fisk, Nm; Talbert, Dg; Rodeck, Ch; Kochenour, Nk; Greco, Pantaleo; Hubinont, C; Santolaya, J.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/2333370
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 64
  • ???jsp.display-item.citation.isi??? 49
social impact