We report radiation hardness tests performed, with a white neutron beam, at the Geel Electron LINear Accelerator in Belgium on silicon Photo-Multipliers. These are semiconductor photon detectors made of a square matrix of Geiger-Mode Avalanche photo-diodes on a silicon substrate. Several samples from different manufacturers have been irradiated integrating up to about 6.2 × 10 9 1-MeV-equivalent neutrons per cm2. © 2013 IEEE.
Silicon photo-multiplier radiation hardness tests with a white neutron beam
ANDREOTTI, Mirco;CALABRESE, Roberto;LUPPI, Eleonora;TELLARINI, Giulia;TOMASSETTI, Luca;
2013
Abstract
We report radiation hardness tests performed, with a white neutron beam, at the Geel Electron LINear Accelerator in Belgium on silicon Photo-Multipliers. These are semiconductor photon detectors made of a square matrix of Geiger-Mode Avalanche photo-diodes on a silicon substrate. Several samples from different manufacturers have been irradiated integrating up to about 6.2 × 10 9 1-MeV-equivalent neutrons per cm2. © 2013 IEEE.File in questo prodotto:
Non ci sono file associati a questo prodotto.
I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.