Background: The appropriate positioning of nerve integrity monitoring during thyroid surgery is of relevance. In this case report we describe our experience with accurate placement of a nerve integrity monitoring endotracheal tube, obtained by fiberoptic control, in a patient with expected difficult airway management. Case presentation: We report the case of a 70-year-old obese woman scheduled for elective total thyroidectomy due to plunging intrathoracic goiter. The preoperative indirect laryngoscopy pointed out a massive bombè of the hypopharyngeal wall to the right and right vocal cord paralysis. The epiglottis was oedematous and the glottis could not be identified. On physical examination, the tongue was large, and a Mallampati’s score of 3 was determined. Hence, due to an expected difficult airway management, a nasal intubation with an electromyographic nerve integrity monitoring endotracheal tube trough fiberoptic bronchoscopy was successfully performed. Conclusion: Our experience suggests that nasal intubation can be safely performed by using a nerve integrity monitoring tube with the help of fiberoptic bronchoscopy.
Successful nasal intubation with a laryngeal nerve monitoring tube using bronchoscopy in a patient with plunging goiter: A case report
Spadaro SPrimo
;Verri M;Ragazzi RPenultimo
;Volta CA.
Ultimo
2013
Abstract
Background: The appropriate positioning of nerve integrity monitoring during thyroid surgery is of relevance. In this case report we describe our experience with accurate placement of a nerve integrity monitoring endotracheal tube, obtained by fiberoptic control, in a patient with expected difficult airway management. Case presentation: We report the case of a 70-year-old obese woman scheduled for elective total thyroidectomy due to plunging intrathoracic goiter. The preoperative indirect laryngoscopy pointed out a massive bombè of the hypopharyngeal wall to the right and right vocal cord paralysis. The epiglottis was oedematous and the glottis could not be identified. On physical examination, the tongue was large, and a Mallampati’s score of 3 was determined. Hence, due to an expected difficult airway management, a nasal intubation with an electromyographic nerve integrity monitoring endotracheal tube trough fiberoptic bronchoscopy was successfully performed. Conclusion: Our experience suggests that nasal intubation can be safely performed by using a nerve integrity monitoring tube with the help of fiberoptic bronchoscopy.File | Dimensione | Formato | |
---|---|---|---|
1870361985102873_final.pdf
solo gestori archivio
Tipologia:
Altro materiale allegato
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
1.27 MB
Formato
Adobe PDF
|
1.27 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Successful-nasal-intubation-with-a-laryngeal-nerve-monitoring-tube-using-bronchoscopy-in-a-patient-with-plunging-goiter-A-case-report2013BMC-Research-NotesOpen-Access.pdf
accesso aperto
Descrizione: versione editoriale
Tipologia:
Full text (versione editoriale)
Licenza:
Creative commons
Dimensione
615.05 kB
Formato
Adobe PDF
|
615.05 kB | Adobe PDF | Visualizza/Apri |
I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.