At Legnaro laboratories of the Italian National Institute for Nuclear Physics (INFN), a feasibility study has started since 2011 related to accelerated-based direct production of by the 100Mo(p,2n) reaction. Both theoretical investigations and some recent preliminary irradiation tests on 100Mo-enriched samples have pointed out that both the / ratio and the specific activity will be basically different in the final accelerator-produced Tc with respect to generator-produced one, which might affect the radiopharmaceutical procedures. The aim of this work was to evaluate the possible impact of different / isomeric ratios on the preparation of different Tc-labeled pharmaceutical kits. A set of measurements with , eluted from a standard 99Mo/ generator, was performed, and results on both radiochemical purity and stability studies (following the standard quality control procedures) are reported for a set of widely used pharmaceuticals (i.e., -Sestamibi, -ECD, -MAG3, -DTPA, -MDP, -HMDP, -nanocolloids, and -DMSA). These pharmaceuticals have been all reconstituted with either the first [O4]− eluate obtained from a 99Mo/ generator (coming from two different companies) or eluates after 24, 36, 48, and 72 hours from last elution. Results show that the radiochemical purity and stability of these radiopharmaceuticals were not affected up to the value of 11.84 for the / ratio.

Influence of the Generator in-Growth Time on the Final Radiochemical Purity and Stability of Radiopharmaceuticals

UCCELLI, Licia;BOSCHI, Alessandra;PASQUALI, Micol;DUATTI, Adriano;DI DOMENICO, Giovanni;PUPILLO, Gaia;GIGANTI, Melchiore;TAIBI, Angelo;GAMBACCINI, Mauro
2013

Abstract

At Legnaro laboratories of the Italian National Institute for Nuclear Physics (INFN), a feasibility study has started since 2011 related to accelerated-based direct production of by the 100Mo(p,2n) reaction. Both theoretical investigations and some recent preliminary irradiation tests on 100Mo-enriched samples have pointed out that both the / ratio and the specific activity will be basically different in the final accelerator-produced Tc with respect to generator-produced one, which might affect the radiopharmaceutical procedures. The aim of this work was to evaluate the possible impact of different / isomeric ratios on the preparation of different Tc-labeled pharmaceutical kits. A set of measurements with , eluted from a standard 99Mo/ generator, was performed, and results on both radiochemical purity and stability studies (following the standard quality control procedures) are reported for a set of widely used pharmaceuticals (i.e., -Sestamibi, -ECD, -MAG3, -DTPA, -MDP, -HMDP, -nanocolloids, and -DMSA). These pharmaceuticals have been all reconstituted with either the first [O4]− eluate obtained from a 99Mo/ generator (coming from two different companies) or eluates after 24, 36, 48, and 72 hours from last elution. Results show that the radiochemical purity and stability of these radiopharmaceuticals were not affected up to the value of 11.84 for the / ratio.
2013
Uccelli, Licia; Boschi, Alessandra; Pasquali, Micol; Duatti, Adriano; DI DOMENICO, Giovanni; Pupillo, Gaia; J., Esposito; Giganti, Melchiore; Taibi, Angelo; Gambaccini, Mauro
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/1867315
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 18
social impact