BACKGROUND: Titanium dioxide exists in three different crystal lattices, anatase, rutile, and brookite. Anatase coating releases, under ultraviolet (UV) irradiation, free radicals such as ·OH, O2 (-), HO2 (-), and H2O2. This potent oxidizing power characteristically results in the lysis of bacteria and other organic substances. The purpose of this study was to evaluate the bone response to implants made of titanium alloy or coated with a new combination of anatase and Bactercline(®) product. MATERIALS AND METHODS: In the period between July 2009 and June 2010, 26 patients (10 females and 16 males; median age 51 ± 11 years, min. 27 years, max. 72 years) were operated and 62 implants were inserted. Lost fixtures and peri-implant bone resorption were considered as predictors of clinical outcomes. Pearson χ(2)-test was used. Prosthesis and implant failures, any complications after loading, and peri-implant marginal bone-level changes were assessed by a masked assessor. All patients were followed up to 1 year after loading. RESULTS: No implant was lost. Average bone resorption around implant was 0.33 mm (both for 25 standard and 37 Bactercline-coated implants), and thus no statistical difference was detected. CONCLUSION: These results shown that no adverse effects on osseo-integration were present.

Bactercline(®)-coated implants: Clinical results up to 1 year after loading from a controlled clinical trial

CARINCI, Francesco;BIGNOZZI, Carlo Alberto;
2012

Abstract

BACKGROUND: Titanium dioxide exists in three different crystal lattices, anatase, rutile, and brookite. Anatase coating releases, under ultraviolet (UV) irradiation, free radicals such as ·OH, O2 (-), HO2 (-), and H2O2. This potent oxidizing power characteristically results in the lysis of bacteria and other organic substances. The purpose of this study was to evaluate the bone response to implants made of titanium alloy or coated with a new combination of anatase and Bactercline(®) product. MATERIALS AND METHODS: In the period between July 2009 and June 2010, 26 patients (10 females and 16 males; median age 51 ± 11 years, min. 27 years, max. 72 years) were operated and 62 implants were inserted. Lost fixtures and peri-implant bone resorption were considered as predictors of clinical outcomes. Pearson χ(2)-test was used. Prosthesis and implant failures, any complications after loading, and peri-implant marginal bone-level changes were assessed by a masked assessor. All patients were followed up to 1 year after loading. RESULTS: No implant was lost. Average bone resorption around implant was 0.33 mm (both for 25 standard and 37 Bactercline-coated implants), and thus no statistical difference was detected. CONCLUSION: These results shown that no adverse effects on osseo-integration were present.
2012
Carinci, Francesco; E., Grecchi; Bignozzi, Carlo Alberto; G., Murmura; A., Piattelli; A., Scarano
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in SFERA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11392/1829321
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact